Semiconductor production process and testing process temperature control equipment
Use fluid fluorinated liquid for temperature control (minimum -100 degrees)
Gas cold and hot rapid temperature change thermal chuck
Low temperature gas cooler -120 degrees
Direct cooling cooling unit (-150 degrees)
The heating method within 40°C is heated by compressor hot air.
The Chiller ring system adopts a fully enclosed design and a magnetic drive pump.
Chiller100% helium detection, 100% safety inspection, to ensure safety and reliability.
chiller100% after 24 hours of continuous operation copy machine.

Condensador: micro-channel heat exchanger (air-cooled) plate heat exchanger (water-cooled)
Evaporador: Plate heat exchanger Throttling device: Electronic expansion valve Circulation system: The whole system is a fully closed system, low temperature does not absorb moisture in the air, does not volatilize heat transfer medium, low temperature automatically replenishes heat transfer medium into the circulation system.
Shell material: cold-rolled plate spray RAL7035
Inside the pipeline: including stainless steel SUS304, copper, ceramics, broken silicon, silicone sealant, PTFE
Control system: PLC programmable controller
Communication protocol: RS485 interface Modbus RTU protocol
Interfaz Ethernet Protocolo TCP/IP
Operation interface: LNEYA customized 7-inch color touch factory temperature curve display\EXCEL data export
La bomba de frecuencia variable puede ajustar la presión hidráulica de circulación y el caudal
The output pressure and flow rate of circulating fluid can be set on the operation panel. Even under various customer piping conditions, without bypass piping adjustment, the output pressure can be automatically controlled at the set output pressure through the frequency conversion pump. Thereby, the power consumption of a pump can be reduced. Depending on the flow rate, bypass piping may be required
Circulation heating is possible without a heater because it is heated by the exhausted heat
Recomendaciones relacionadas
-
10L reactor temperature control equipment
178210L reactor temperature control equipment, also known as oil bath machine, is a device used to accurately control the temperature in the reactor, usually through heat transfer oil (also known as heat transfer fluid) to achieve heating and cooling....
Ver detalles -
Water Distiller Circulating Chiller
1684Water distillers generate a lot of heat during operation, especially when they need to run continuously or process a large amount of water. In order to ensure that the water distiller can operate stably and maintain efficient distillation efficien...
Ver detalles -
Control de la temperatura y enfriadores en el proceso de difusión por oxidación
1680El proceso de difusión por oxidación es un paso clave en la fabricación de semiconductores. Se utiliza principalmente para formar capas de óxido y dopaje precisas, y tiene unos requisitos extremadamente estrictos de control de la temperatura. En este proceso, el enfriador, como imp...
Ver detalles -
Principio de mantenimiento del sistema de control de temperatura TCU de líquidos fluorados
1901El sistema de control de temperatura TCU de líquido fluorado debe colocarse en un lugar ventilado, seco y limpio; (2) La distancia entre el sistema de control de temperatura TCU de líquido fluorado y el tabique es superior a 1m; (3) El lo...
Ver detalles
工業冷水機製造商 LNEYA Taiwan