Utilisation et entretien du système de contrôle de la température du laboratoire/de la bio-ingénierie
1. Read the equipment manual carefully before use, get familiar with the operation process and key instructions, and operate in strict accordance with the conditions specified in the manual.
2. When moving the laboratory/bioengineering temperature control system, avoid striking the equipment shell, vibrating and damaging or polluting the keypad (function key display).
3. Before use, make sure to regularly check (at least once every two years) whether the equipment is in normal working condition.
4. The laboratory/bioengineering temperature control system shall be stored or used in a clean environment with sufficient fresh air to prevent pollution. There is more than 30cm space around, and the ground is flat and firm. Ensure that the input power is properly grounded when using.
5. Before any repair, maintenance or moving the equipment, the equipment must be turned off and the power supply must be disconnected. The tilt angle of the laboratory/bioengineering temperature control system should not exceed 15 degrees when moving. When the laboratory/bioengineering temperature control system needs to move for a long distance, it is necessary to empty the liquid in the equipment and carefully check the pipe connections to ensure that there is no leakage.
6. When selecting the heat conduction medium, pay attention to whether its upper and lower temperature limits, ignition point, viscosity, freezing point, etc. meet the requirements, and whether it is suitable for the use of the internal pipes of the instrument. Use the heat conduction medium specified by the manufacturer and within the specified pressure range.
7. When selecting the heat transfer medium pipe, the length should be as short as possible and the diameter should be as large as possible. If the diameter is too small, it may cause flow restriction. Do not knot the heat transfer medium pipeline of the high and low temperature all-in-one machine, and check it regularly to avoid material strain (such as fission).
8. Regularly check the liquid sight glass on the side of the equipment to confirm whether the liquid level of the heat transfer medium is at the normal position. Regularly replace the thermal conductivity medium of the laboratory/bioengineering temperature control system. If water is mixed with immiscible oil and water, the mixed liquid will expand after heating, and will spray under high temperature, even causing personal injury.
9. The equipment adjustment parameters must be reset after the new heat conduction medium is filled.
The above are technical maintenance and use matters. If you have other information needs about the equipment, you can leave a message to us, or even send an email to sales@lneya.com
Recommandations connexes
-
Characteristics of the evaporator of LNEYA screw chiller
2764The amount of cooling capacity of the screw chiller is directly related to the energy consumption and operational economics of the entire unit, which is worthy of attention. Especially when designing a cold station, there is no single chiller in t...
Voir les détails -
L'essai du moteur du compresseur du refroidisseur provoque l'usure
2088La qualité de l'huile de refroidissement des moteurs peut être l'une des principales causes de l'usure du vilebrequin. Si l'huile moteur est utilisée dans le système de réfrigération du refroidisseur, l'huile moteur qui ne répond pas aux exigences et qui est de mauvaise qualité peut provoquer une usure du vilebrequin...
Voir les détails -
Temperature conditions of new energy vehicle batteries
1828When automobile manufacturers continue to improve battery life to overcome the driver's mileage anxiety, the energy density of the large batteries installed is also gradually increasing, which means that the temperature monitoring function of the...
Voir les détails -
Effet de la température sur les réactions de la synthèse organique chimique
2421Organic synthesis is a common chemical phenomenon in chemistry. Temperature has an important influence on it during the whole synthesis process. As the temperature rises, the heat-absorbing reaction will speed up, resulting in a significant change...
Voir les détails
工業冷水機製造商 LNEYA Taiwan