Industry and introduction of low temperature chiller
In petroleum refining, petrochemical industry, organic synthesis, chemical products and other industrial production, refrigeration technology must be applied to control the reaction temperature during processes such as liquefaction, condensation, solidification, separation, refining, crystallization, concentration, and purification.
The chemical industry is mainly used for the cooling and cooling of chemical reaction kettles, and takes away the ordinary heat generated by chemical reactions in time to reach the purpose of cooling (cooling), in order to improve product quality. If the cold water (wind) provided by the refrigerator is used for cooling, not only the product quality can be greatly improved, but also the consumption efficiency can be improved. The pharmaceutical industry is mainly used to control the temperature and humidity of the workshop and to take out the heat of reaction during the process of consuming the drug substance.
Refrigerators in the industry are basically composed of components such as evaporators, single-stage compressors, oil separators, condensers, and liquid storage tanks. LNEYA’s freezer has exclusive technology, the temperature range is -5 ℃ ~ -150 ℃, which can meet different temperatures. This cooler uses international brand Carrier compressor, adopts automatic cascade refrigeration mode and mixed refrigerant, direct cooling ultra-low temperature freezer, single compressor automatic cascade refrigeration technology can freeze to minus 120 ° C in 3 minutes. Before delivery to customers, the production workshop provides machine installation and system testing. Users only need to complete the installation of refrigerant and cooling water.
The working principle of LNEYA low temperature chiller is as follows:
low temgperature chiller appearance:
Recommandations connexes
-
Description du programme de l'équipement de test des puces à mémoire
2186Avec le développement rapide de l'industrie des composants, l'équipement de test des puces à mémoire a également fait de grands progrès. Alors, que savent les utilisateurs de l'équipement de test des puces mémoire ? Afin de simplifier les étapes du test, de réduire la complexité du t...
Voir les détails -
Refrigerating Output of Low Temperature Cooling Circulator
1728The refrigerating output of low temperature cooling circulator varies with different working conditions. So, when the process calculation is carried out at the beginning, it is necessary to set an allowance for the refrigerating output of the heat...
Voir les détails -
Quelles sont les précautions à prendre pour l'installation d'un refroidisseur au glycol ?
2031En été, l'utilisation des refroidisseurs de glycol est relativement fréquente. Par conséquent, lors de l'installation des refroidisseurs de glycol, il est nécessaire de les installer sur un sol lisse et propre. Pourquoi choisir un sol lisse lors de l'installation ? Les utilisateurs qui ont connu les refroidisseurs de glycol...
Voir les détails -
Le système de refroidissement du moteur teste l'effet de la température de condensation
2396The motor cooling system tests the condenser. Under normal conditions, the first half of the heat pipe is very hot, and its temperature has a slow and slow gradual decline in the balance of power. The heat sensitivity of the second half of the hea...
Voir les détails