There are certain differences in the use method, function, structure, etc. of different types of chiller cooling systems for low-temperature operation test.
The chiller of the industrial low-temperature operation test requires heat to be generated during operation. The cooling air should be circulated. There should be a certain space around the installation, and the generated heat should be dissipated upwards, so do not install it around equipment that is not heat-resistant. The chiller of the industrial low-temperature operation test cooling system should be installed directly on the horizontal surface. Do not install it upside down, diagonally or vertically.
The chiller cooling system for industrial low-temperature operation test cannot be installed in places where there are various fibers, paper (chips), metal fragments, etc. The water outlet of the chiller cooling system for industrial low-temperature operation test should be connected with the water inlet of your instrument, and the water outlet of the instrument should be connected with the water inlet of the cooling circulating water machine.
Check whether the air filter, heat exchanger coils and fins of the air-cooled low-temperature operation test cooling system chiller are too dusty. Is the air inlet and outlet dredged? Is the fan and fan blade working normally? Is the wind power normal? Is the water system normal?
Check if the chiller water system of the air-cooled low-temperature operation test cooling system is leaking. Is the water inlet and outlet dredged? Is the pump working normally? Listen to the power on and listen to the air-cooled low-temperature operation test cooling system chiller compressor working sound is normal, whether there is abnormal sound, whether the electric fan, water pump is noisy, whether the noise is too loud, etc. The chiller of the air-cooled low-temperature operation test cooling system is in operation, and under normal conditions, the oscillation is slight and the noise is small.
Check the air-cooled low-temperature operation test cooling system chiller refrigeration system for cracks, damage, frost and condensation and other conditions in the pipes. Whether there is friction between the chiller refrigeration pipes of the air-cooled low-temperature operation test cooling system, the pipes and the shell, etc., especially the welding place of the refrigerant pipe, and whether there is the connection of the chiller joint of the air-cooled low-temperature operation test cooling system Leakage, as long as there is a leak, there will be oil stains. You can also use a clean soft cloth or soft paper to scrub the welded joints and joints of the pipeline, and investigate whether there is any oil stains to determine whether there is a leak.
Check whether the electrical system fuse of the air-cooled low-temperature operation test cooling system chiller is blown, whether the insulation of the electrical wire is intact, whether the circuit board is cracked, whether the connection is loose, etc. Especially if the electrical connection is excellent in touch, the wiring screws and connectors are easy to loose and cause poor touch.
Recommandations connexes
-
Instructions for using the hydrogenation reactor cooling and heating integrated system
2270There are many accessories in the hydrogenation reactor cooling and heating integrated system, from the compressor to the electrical components. LNEYA reminds you that if you find more evaporator freezing oil, it is recommended to deal with it in ...
Voir les détails -
À quoi dois-je faire attention lors du remplacement d'un compresseur de refroidisseur à eau ?
1942Lorsque le compresseur du refroidisseur à eau tombe en panne, il doit être remplacé à temps, mais le remplacement du compresseur n'est pas aussi simple qu'on l'imagine.Avant de remplacer le compresseur du refroidisseur à eau, les raisons de la dama...
Voir les détails -
Machine à refroidir l'eau chaude et froide à haute et basse température pour tester les moteurs de batteries
1948LNEYA high and low temperature cold and heat integrated water cooler is used in battery thermal management of new energy electric vehicles. The following is the relevant principle applied in thermal management. The high and low temperature cold an...
Voir les détails -
Le tournoi de badminton LNEYA 2020 s'est achevé avec succès
1943Afin d'enrichir le temps libre des employés, de renforcer la cohésion entre eux, de créer une atmosphère de travail ensoleillée, énergique et passionnée, et de démontrer l'esprit positif, sain et ascendant de l'entreprise, LNEYA a organisé la troisième "Guanya Cup" de badminton...
Voir les détails
工業冷水機製造商 LNEYA Taiwan