What is the reason why the industrial chiller system cannot be cooled
Let the LNEYA technical engineer explain
the reason for everyone:
The first one: The chiller system fails to
lower the temperature during the first use, or there is a problem with the
installation of the industrial water chiller, cooling tower, circulating water
pump and piping. Need to check carefully according to the installation drawing.

The second one: It may be because the
pipeline is connected to various equipment for a long time, and impurities
accumulate in the water source, which causes the water flow to become smaller.
Therefore, we must clean the pipes between the equipment.
Third: If this problem occurs during the
first use, it may be caused by a mismatch of the chiller and a shipping
problem. Because the industrial water chiller has undergone 100% performance
testing before leaving the factory to ensure the normal operation of the unit.
Finally, if it is a chiller that has been
used for half a year or 1-2 years, it may be caused by a leak of Freon in the
cooling system of the chiller. It is recommended to find out the leaks,
re-soldering, and re-soldering the refrigerant. The heat exchanger of the
industrial water chiller is dirty and needs to be cleaned. Remember to clean it
regularly in the future.
The operation of any industrial water chiller
system is inseparable from the participation of refrigerants. Therefore, the
shortage of refrigerant will also affect the normal operation of industrial
chillers, leading to reduced cooling capacity or even shutdown
of industrial water chillers. This is also the main reason for the shrinking
capacity of industrial chillers.
Recommandations connexes
-
Measures for stable operation of short-range molecular distiller
1878If the short-range molecular distiller is inefficient during operation, it will affect the use of the associated refrigeration heating temperature control system. How does the short-range molecular distiller maintain stable operation? If the steam...
Voir les détails -
What are the characteristics of the pressure of industrial water chillers
2222Industrial water chillers are one of the most popular equipment in the machinery and equipment industry. For this reason, the editor of LNEYA specially compiled relevant pressure instructions to help everyone better understand industrial water chi...
Voir les détails -
Le rôle de l'unité de contrôle de la température de la réfrigération chimique
1988Dans les usines pharmaceutiques et chimiques, les matières premières contenues dans les réacteurs impliqués dans la production industrielle nécessitent un refroidissement et une réfrigération rapides. Pour atteindre cet objectif, le réacteur subit une réfrigération et un refroidissement directs, ce qui indique...
Voir les détails -
LNEYA isolation explosion-proof cooling heating circulation system SR-35N
1426LNEYA isolation explosion-proof cooling and heating circulation system mainly uses heat transfer medium for heating and refrigerant for cooling. So what are the main accessories in the isolated cold and hot water circulation system? What effect do...
Voir les détails
工業冷水機製造商 LNEYA Taiwan