Explosion-proof hot and cold machine winter maintenance instructions
When the explosion-proof type hot and cold integrated machine is used at the end of the day or when it is not used by the standby, be sure to disconnect the cooling water connection pipe, clean the remaining cooling water in the pipe, and store it in a dry place to prevent freezing and expansion. Damage to machine parts (such as coolers, pumps, connecting copper pipes). The method of removing residual water is as follows:
1. The water sequence series needs to disconnect the cooling water and hot water inlet and outlet pipes and open the corresponding ball valve. Take the air gun to the hot water (outlet) inlet and let the residual medium inside the system discharge from the cooling water inlet (cooling) The water outlet is discharged from the inlet due to the electromagnetic valve. It is determined that there is no water in the pipeline and it can be stopped.
2. The standard explosion-proof type hot and cold integrated machine needs to disconnect the connecting pipe of the cooling water inlet and outlet, open the ball valve and let the machine be in a cooling state. When the cooling electromagnetic valve is opened, take the air gun and blow it into the cooling water inlet to make it from the water outlet. Discharge, determine that there is no water in the pipeline and then stop.
Kindly note, please be sure to disconnect the cooling water connection pipe when the equipment is not in use, and clean the remaining cooling water/heat transfer oil in the pipe, and store it in a dry place.
In the winter, when you do not need the explosion-proof type hot and cold machine, you need to pay attention to turn off the explosion-proof hot and cold machine and clean it as well, so as to avoid the residue affecting the performance of the explosion-proof hot and cold machine.
Recommandations connexes
-
What is the lack of oil in the 120-degree ultra-low temperature refrigerator?
2173The compressor of the -120 degree ultra-low temperature refrigerator is a complex component that runs at high speed. In order to ensure sufficient lubrication of the moving parts of the compressor crankshaft, bearings, connecting rods, pistons, et...
Voir les détails -
Introduction of distillation principle and temperature cycle control device
1895Distillation is a common method for purifying liquid substances and separating mixtures. The boiling point of the compound can also be measured by distillation, so it also has a certain significance for the identification of pure liquid organic co...
Voir les détails -
Traitement des gaz d'échappement insuffisants dans les compresseurs à chambre d'essai d'impact à haute et basse température
2158L'efficacité de la chambre d'essai d'impact à haute et basse température pendant l'utilisation est très importante. S'il y a un manque de gaz d'échappement du compresseur, nous avons besoin de nos techniciens LNEYA pour résoudre le problème à temps. Alors, comment mieux résoudre le problème ?
Voir les détails -
New energy vehicle high and low temperature test system
1858With the popularity of new energy vehicles, high and low temperature tests have become a factor that car owners need to consider when purchasing new energy vehicles. Since the environment in which new energy vehicles are used is harsher, it is als...
Voir les détails
工業冷水機製造商 LNEYA Taiwan