Fully closed cycle high viscosity fluid refrigeration heating flow control system
Application :
1. The tested object is connected to a test platform adapter.
2. The internal parts of the parts are cooled, heated, flow controlled, and pressure controlled by various lubricating oils, hydraulic oils, aviation fuel, fuel oil, and coolant.
Le composant testé doit passer par un profil de température spécifique et enregistrer les changements de température.
4. When conducting the tolerance test, perform the thermal shock test, and the rapid temperature drop control usually takes place in an infinite loop.
Visualisation, stockage des données et analyse des rapports
6, temperature control equipment can be flexibly connected to other test platforms
7. Equipped with a powerful circulation pump to ensure the delivery of high viscosity liquids.
8. The range of temperature changes is usually from -50 to 200 degrees (which can be made wider).
9. The proportional control valve is used to control the flow output, and the high-precision control total range is adjusted from 5% to 100%. The flow control range is large, and the minimum flow rate can be controlled from 3L/H to a maximum of 100m3/H.
10, pressure control 0.1bar ~ 20bar
11. The fully enclosed circulation system avoids the contact between the medium and the outside air, ensures no condensation, and avoids oxidation of the medium.
Recommandations connexes
-
Defrosting Method of Ultra Low Temperature Freezer
1978Defrosting method from the top 10 manufacturers of ultra low temperature freezer Wuxi Guanya = There are many manufacturers of ultra low temperature freezer, Wuxi Guanya is one of them. Many enterprise users don't know much about the defrosting af...
Voir les détails -
Precautions for the Placement of Industrial Air Cooled Chiller
2748The quality and use of industrial air cooled chillers are very important. At the same time, the user operation cannot ignore the position placement. Only the correct position placement and high-quality equipment can achieve high-efficiency operati...
Voir les détails -
Instructions de vidange et de remplissage du testeur linéaire de changement rapide de température
2128Avant de démarrer le testeur linéaire de changement rapide de température, vérifiez si les mesures de protection appropriées sont en place, telles que la protection contre l'incendie, la protection, la prévention des fuites et d'autres outils. Vérifiez que l'alimentation électrique est en place conformément à ...
Voir les détails -
Les équipements mécaniques d'assemblage à froid sont dédiés à l'assemblage à froid de pièces métalliques.
1796L'équipement d'assemblage mécanique à froid est une méthode de traitement des pièces à des températures inférieures à -130℃. Le traitement cryogénique peut améliorer de manière significative la ténacité de la pièce sans en réduire la résistance et la dureté. Mécanique...
Voir les détails
工業冷水機製造商 LNEYA Taiwan











