Guidelines for Safe Use and Maintenance of Ultra-Low Temperature Freezer
Cryopreservation of samples is very important in modern biological research.
Correct use of cryogenic freezers (hereinafter referred to as refrigerators):
1. It is necessary to understand the influence of environment on refrigerators.
2. Familiar with basic operation, maintenance and maintenance knowledge
3. Develop good habits
Let the refrigerator breathe freely;
Let the air around the refrigerator circulate freely.
Free at least 15 cm of space around the refrigerator and 30 cm of space at the top.
Items should not be stacked at the top of the refrigerator to avoid affecting the heat dissipation at the top.
Give the refrigerator a reliable environment
Try to keep the ambient temperature around the refrigerator between 15 and 32 degrees Celsius for a long time.
Consider the difference of energy consumption between winter and summer, and control the environmental temperature reasonably.
If the ambient temperature is too high for a long time, the compressor life will be damaged.
Refrigerator heat dissipation will lead to higher ambient temperature
Eliminate the influence factors of heat exchange in refrigerators:
Don’t put the refrigerator near the heat source
Don’t put the refrigerator in the vent
Reserve special circuit for refrigerators
Basic operation
Turn on: After plugging in the power plug, press the switch in the lower right corner of the back, “O” stands for turning off, and “I” stands for turning on.
If the equipment is inclined more than 45 degrees when it is moved, the equipment will be placed vertically for 24 hours before start-up!!!
Open the battery switch: Open the white door under the front and press the switch down to “I”
Battery function: When the power is off, it can supply power to the display board and provide sound and light alarm.
We are a ultra low temperature freezer manufacturer. Welcome to choose our products.
Recommandations connexes
-
Manufacturer explains what are the influences of the oil level and oil difference of the chiller?
2210The chiller manufacturer tells everyone that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil reservoir and special oil cooler. Therefore, we must understand the influence of the oil l...
Voir les détails -
How to solve the problem that the cooling pump centrifugal pump power consumption becomes larger?
2003There are many opportunities for the centrifugal pump in the chiller, but the failure of the centrifugal pump will affect the use of the chiller. Therefore, do not worry if the centrifugal pump power becomes larger, find out the cause in time, and...
Voir les détails -
Instructions for cold assembly of bearings in ultra-low temperature industrial refrigerators
1869The refrigeration system of ultra-low temperature industrial refrigerators generally adopts the working principle of cascade refrigeration, and two fully enclosed compressors are used as high and low temperature compressors. The copper tube of the...
Voir les détails -
Flux de travail et composition de l'équipement pour le raffinage et le déparaffinage du pétrole
2023The oil dewaxing process is based on the melting point difference between the wax and the oil and the solubility of the wax in the oil becomes smaller as the temperature decreases, and the crystalline wax is precipitated by cooling. Then through t...
Voir les détails
工業冷水機製造商 LNEYA Taiwan