Usage Details of High and Low Temperature Environmental Chambers
The enterprise users must have a certain understanding of the functions of the high and low-temperature environmental chamber after using them for a long time, but something detail of the high and low-temperature environmental chamber may still not be paid attention to, so the technology department of Wuxi LNEYA has specially reorganized the related matters of attention for everyone.
Professional manufacturer of high and low-temperature environmental chambers for sale
When delivering, the tilted angle of the high and low-temperature environmental chamber should not exceed 30°. When carrying, keep the body of the high and low-temperature environmental chamber vertically, do not place it inversely or horizontally. Besides, dragging the door handle or the condenser are prohibited, otherwise, the equipment may be damaged.
The high and low-temperature environmental chamber should be electrified regularly every month during the lengthy shutdown period, and the power-on time should be more than 1h.
Professional manufacturers of high and low-temperature environmental chamber insist on taking out the test samples after each test and wipe the workroom wall of the environmental chamber to keep the inner box clean.
Cleaning and balance of the circulating blade and condenser fan: Similar to that of the cleaning evaporator, because the working environment of the environmental chamber is different, a lot of small particles like dust will condense on the circulating blade and condenser fan. Hence, they should be cleaned regularly.
The power supply voltage of the high and low-temperature environmental chamber fluctuations, such as repeated power failure. In this case, it is suggested to suspend the use of high and low-temperature environmental chamber and close the power supply to prevent the burning of the compressor. Do not start the compressor immediately after the shutdown of the high and low-temperature environmental chamber. It should be stopped for 2-5 minutes before restarting.
The condenser of the high and low-temperature environmental chamber should be cleaned every three months. The condensing fan should be regularly overhauled and the condenser should be cleaned and dedusted so as to ensure its good ventilation and heat transfer performance.
High and low-temperature environmental chamber should be placed in a well-ventilated position with low humidity and smooth ground, 60 ~ 70 cm of use and maintenance space should be left around.
During the operation of high and low-temperature environmental chamber, the frequency of door opening should be minimized and the spillage of cold air should be reduced.
The usage details of high and low-temperature environmental chamber should be used by enterprise users in daily use.
Recommandations connexes
-
Precautions for cooling and heating during operation of various reactors
1890In many laboratories, various reaction vessels of chemical companies are indispensable reaction vessels, and its operating temperature: -80°C-250°C. The laboratory reactor works at normal temperature, and cooling water must be passed normally to a...
Voir les détails -
Vehicle high temperature and high humidity test vehicle anti-aging performance
2009On test benches in the automotive industry, accurate temperature simulation is critical. From the time of the test, the air temperature in the test chamber has always been maintained at 45 ℃, which is equivalent to the hottest area of the Flaming...
Voir les détails -
Attention points for the use of laboratory chiller manufacturers’ equipment
1720In the laboratory, a wide range of experimental instruments are widely used. When the experimental instruments are in operation, they are inseparable from the high-low temperature circulating device refrigeration heating equipment. What should be ...
Voir les détails -
L'application du congélateur à plaques froides
1762Le système de réfrigération du congélateur à plaques froides adopte la technologie du super-refroidissement secondaire avec une réfrigération rapide et une température limite basse. Il utilise des compresseurs à piston semi-hermétiques de marque importée, des compresseurs composés à piston semi-hermétiques...
Voir les détails
工業冷水機製造商 LNEYA Taiwan











