Précautions pour l'installation d'un refroidisseur spécial pour l'essai des nouvelles énergies
The installation of the special chiller for new energy testing is an important link before operation. The quality of the installation is directly related to the operation and operation status of the special chiller for new energy testing. So, what should be paid attention to in the installation of the special chiller for new energy testing?
If the special chiller for new energy test adopts semi-hermetic or fully-hermetic compressor, an oil separator should be installed, and an appropriate amount of oil should be added to the installed oil separator. When the evaporation temperature is lower than -15 degrees, a gas-liquid should be installed. Separator and add appropriate amount of refrigeration oil. Secondly, the compressor base should be installed with a shock-absorbing rubber seat, and the installation of the special chiller for new energy testing should leave a maintenance space to facilitate the observation of the adjustment of instruments and valves.
The high pressure gauge of the special chiller for new energy testing should be installed at the tee of the liquid storage and filling valve. The overall layout of the special chiller for new energy testing is reasonable and the color is the same. The installation structure of each type of unit should be consistent.
When debugging the special chiller for new energy test, it is necessary to pay attention to measuring the power supply voltage, measuring the resistance value of the three windings of the compressor and the insulation of the motor, checking the opening and closing of each valve of the refrigeration system, and pouring the refrigerant into the storage liquid to the standard charge after evacuation. 70%-80% of the filling volume, and then run the compressor, add air from low pressure to enough volume.
After the special chiller for new energy test is turned on, first listen to whether the sound of the compressor is normal, check whether the condenser and air cooler are running normally, and whether the three-phase current of the compressor is stable. After the special chiller for new energy test cools down smoothly, check the exhaust pressure, suction pressure, exhaust temperature, suction temperature, motor temperature, crankcase temperature, and expansion valve temperature in the refrigeration system, and observe the frosting of the evaporator and expansion valve. , observe the oil level and color change of the oil glass. Check whether the sound of the special chiller for new energy testing is abnormal.
Another point is that the special chiller for new energy testing needs to pay more attention to its maintenance knowledge and carry out a lot of related maintenance work.
Recommandations connexes
-
Is the temperature control equipment for semiconductor component testing a chiller?
1627Semiconductor component testing temperature control equipment is used in the simulation test of the temperature performance of semiconductors, chips and other components, and conducts temperature tests in different temperature ranges within the ra...
Voir les détails -
Vous connaissez les problèmes techniques à connaître avant d'acheter une chambre à basse température
1662Question 1: Is the temperature change rate of temperature impact test the faster the better? Explanation: Is the temperature change rate faster and better in the temperature impact test? Does the temperature change rate have any effect on the tes...
Voir les détails -
Selection of Temperature Control System for Laboratory Resin Reaction Kettle
19311. Choose from the quality of the laboratory resin reactor temperature control system: can affect the quality of the laboratory resin reactor temperature control system, may be the use of accessories. There are some small factories on the market t...
Voir les détails -
Quelles sont les précautions à prendre pour l'installation d'un refroidisseur au glycol ?
2031En été, l'utilisation des refroidisseurs de glycol est relativement fréquente. Par conséquent, lors de l'installation des refroidisseurs de glycol, il est nécessaire de les installer sur un sol lisse et propre. Pourquoi choisir un sol lisse lors de l'installation ? Les utilisateurs qui ont connu les refroidisseurs de glycol...
Voir les détails