2. Air-cooled module internal filter, in order to better filter impurities in the water system, the protective plate heat exchanger is generally more than 40 meshes, that is to say, its filter is more dense and finer than other brands. The advantage of this method is that it can filter impurities better, and the disadvantage is that the number of cleaning increases. But compared with the air-cooled module machine, the closed circulating water system can better ensure the cleaning of the water system in the future as long as the filters are cleaned in time during the initial operation.
3. Inspection and cleaning of end filters. Water filters are installed in both air conditioning boxes and fan coil units at the end. These water filters need to be checked and cleaned, which is also an indirect reason affecting the water system and can improve the cooling effect of the end.
4. We can’t start it forcibly. We are used to turning it on when something goes wrong. In fact, it is a serious operation error for water chiller, especially the frequent power failure and reset of the chiller, which results in the failure of protection, just like a car with frequent high water temperature failure and failure to deal with it, which eventually leads to the breakdown.
Our company provides small water chiller units, welcome to buy!
Recommandations connexes
-
With these points, the use efficiency of the ultra-low temperature chiller can be more efficient
2018The structure of the ultra-low temperature chiller is more complicated. Its main function is to provide cold air to the product, which is the refrigeration function. If you want to improve the efficiency of the freezer, you must pay attention to t...
Voir les détails -
What are the applications of Industrial temperature control machine chillers?
2336Industrial temperature control machine chillers are divided into oil-cooled and water-cooled according to the temperature and medium. The medium used is different for different temperatures, water can be selected for normal temperature, heat tra...
Voir les détails -
What is the lack of oil in the 120-degree ultra-low temperature refrigerator?
2173The compressor of the -120 degree ultra-low temperature refrigerator is a complex component that runs at high speed. In order to ensure sufficient lubrication of the moving parts of the compressor crankshaft, bearings, connecting rods, pistons, et...
Voir les détails -
Low temperature chilled lubricant selection considerations
2406When you use a cryogenic chilled, you definitely want to know about all aspects of the cryocooler. But one of the things that needs everyone's attention is that the type of lubricant for the chilled is chosen because there are many influencing fac...
Voir les détails
工業冷水機製造商 LNEYA Taiwan