About the size and installation height of refrigeration heating temperature control system equipment
Whether it is biopharmaceutical, traditional Chinese medicine or chemical pharmacy, pharmaceutical companies are all related to chemistry, because the extraction and synthesis of pharmaceutical ingredients are all in the form of chemical products. Therefore, as long as there are many links in the process, there are explosive substances such as acetone, alcohol, etc. There are also raw materials in the warehouse, dust in the workshop, and pressure in the reactor.
Temperature control equipment is essential for these enterprises, and the price is relatively expensive, so such customers are customized explosion-proof cooling and heating units. The explosion-proof standard of our LNEYA is in accordance with national regulations, the explosion-proof mark is Expxdmb Ⅱ CT4, and the explosion-proof qualification is just GYB091118. The positive pressure explosion-proof cabinet is composed of a positive pressure chamber and a control chamber. The positive pressure chamber is used to install various non-explosion-proof instruments or electrical appliances. The control chamber is composed of an explosion-proof control box and a pressure control system. The isolation explosion-proof mark is EXd ⅡBT4, and the electrical cabinet adopts explosion-proof type. Therefore, during the initial communication, our technicians will confirm with the user whether there are explosion-proof requirements.
Here we mainly introduce the hardware data of our LNEYA refrigeration heating temperature control system. Because we accept customer’s customization, we will rationally design the appearance of each plate according to the customer’s use site. Such as the size of the equipment, the position and size of the inlet and outlet, and the installation height. Industrial temperature control equipment will not be miniature, and its length, width and height are definitely higher than that of an adult. Secondly, the pipeline of cooling water circulating water needs to be informed of the working conditions on site, so that the size and position of the inlet and outlet and the data interface area can be determined before production. Normally, the medium inlet and outlet of our equipment is located on the left side of the rear of the equipment, the pressure gauge is located under the left side of the rear, and the data interface is located under the front color control screen. You can take a closer look at the actual appearance of the device.
Recommandations connexes
-
Talk about the main points of choice for circulating water chiller in laboratory
1854Circulating water cooler is also called chiller. It is a kind of cooling water equipment that can provide constant temperature, constant flow and constant pressure. Currently there are many kinds of chillers in the market. How to buy a suitable ch...
Voir les détails -
Introduction to mixed solution of glycol chilling systems (glycol chillers)
1888Glycol chillers are industrial refrigeration systems that use a type of antifreeze called glycol, mixed with water, to lower the freezing point in the application of the chilling system. Glycol is a class of organic compounds that belong to the ...
Voir les détails -
Various reactors and materials use PLC temperature control system
2253The PLC temperature control system is used for the lifting and constant temperature control of glass reactors, metal reactors and bioreactors, especially for heat exothermic control in the reaction process. The heat transfer oil in the jacket of t...
Voir les détails -
Comment les circulateurs isolés de chauffage et de réfrigération gèrent-ils les inefficacités ?
1901La dissipation de la chaleur est un problème courant qui cause des inefficacités dans les circulateurs isolés de chauffage et de réfrigération, et c'est aussi un problème qui peut facilement se produire. De nombreux circulateurs de chauffage et de réfrigération isolés présentent des problèmes similaires.
Voir les détails
工業冷水機製造商 LNEYA Taiwan