L'effet du chauffage et du refroidissement Traducteur
The whole liquid circulation of the heating and cooling circulator is closed with the expansion vessel. The expansion vessel and the liquid circulation are adiabatic and do not participate in the liquid circulation. This is just a mechanical connection. Whether the temperature of the liquid circulation is high or low, the medium in the expansion vessel is always below 60 degrees.
Heating cooling circulator all closed system, extend the life of the thermal fluid, temperature range is extremely wide, with no need to replace liquid medium, the refrigeration system uses air-cooled compressor refrigeration, high cooling speed, low noise, high and low temperature all-in-one airtight microcomputer with internal overtemperature alarm function, upper and lower limits can be arbitrary set within ten degrees, sometimes there are some deviations in the measurement, airtight high and low temperature all-in-one can officially adjust the deviation in the measurement.
What is the function of the heating and cooling circulator? In the commissioning and operation stage of the heating and cooling circulator system, if it is found that the cooling capacity of the cooling and heating circulator system is obviously insufficient and no other abnormalities are found after inspection, attention should be paid to the refrigerant; If the heating cooling circulator system dryer filter or expansion valve block, and the blockage is the browns color wax-like or black sludge form foreign bodies need to focus on refrigerant when hot and cold cycle machine appeared in the process of system running high, low pressure or temperature anomaly, or stop state system balance when abnormal pressure (can control temperature of the refrigerant pressure characteristic table), need to focus on the refrigerant. If these anomalies occur in the heating and cooling circulator, it is recommended that the refrigerant can be extracted from the system for purity testing to screen out the risk of poor refrigerant quality.
Recommandations connexes
-
Qu'est-ce qu'un refroidisseur de glycol de laboratoire ? À quoi dois-je faire attention ?
2368Le refroidisseur de glycol de laboratoire est un équipement de refroidissement courant dans les laboratoires. Il est généralement utilisé pour répondre aux exigences de température de la source froide. Quels sont ses avantages ? 1) Pourquoi choisir un refroidisseur de glycol de laboratoire ?
Voir les détails -
How to install and use the reactor temperature control system?
2073Many users are going to start the installation after purchasing the reactor temperature control system. What should be paid attention to during installation? When installing the reaction kettle of the reactor temperature control system, it is nece...
Voir les détails -
Refrigeration heating and temperature control system of chemical reaction kettle
1846The reaction kettle cooling and heating temperature control system plays a certain role in the temperature control of various materials of reaction kettle, and its temperature control effect affects the results of reaction experiment. The stable o...
Voir les détails -
Introduction to the structure and application of industrial refrigerators
1935Industrial refrigerators are usually called industrial refrigerator boxs, and low-temperature freezers.Temperature range: -150℃~-20℃. Industrial refrigerators can be divided into vertical and horizontal types. Most of them use imported compressors...
Voir les détails
工業冷水機製造商 LNEYA Taiwan