実験室/生物工学温度制御システムの使用とメンテナンス
1. Read the equipment manual carefully before use, get familiar with the operation process and key instructions, and operate in strict accordance with the conditions specified in the manual.
2. When moving the laboratory/bioengineering temperature control system, avoid striking the equipment shell, vibrating and damaging or polluting the keypad (function key display).
3. Before use, make sure to regularly check (at least once every two years) whether the equipment is in normal working condition.
4. The laboratory/bioengineering temperature control system shall be stored or used in a clean environment with sufficient fresh air to prevent pollution. There is more than 30cm space around, and the ground is flat and firm. Ensure that the input power is properly grounded when using.
5. Before any repair, maintenance or moving the equipment, the equipment must be turned off and the power supply must be disconnected. The tilt angle of the laboratory/bioengineering temperature control system should not exceed 15 degrees when moving. When the laboratory/bioengineering temperature control system needs to move for a long distance, it is necessary to empty the liquid in the equipment and carefully check the pipe connections to ensure that there is no leakage.
6. When selecting the heat conduction medium, pay attention to whether its upper and lower temperature limits, ignition point, viscosity, freezing point, etc. meet the requirements, and whether it is suitable for the use of the internal pipes of the instrument. Use the heat conduction medium specified by the manufacturer and within the specified pressure range.
7. When selecting the heat transfer medium pipe, the length should be as short as possible and the diameter should be as large as possible. If the diameter is too small, it may cause flow restriction. Do not knot the heat transfer medium pipeline of the high and low temperature all-in-one machine, and check it regularly to avoid material strain (such as fission).
8. Regularly check the liquid sight glass on the side of the equipment to confirm whether the liquid level of the heat transfer medium is at the normal position. Regularly replace the thermal conductivity medium of the laboratory/bioengineering temperature control system. If water is mixed with immiscible oil and water, the mixed liquid will expand after heating, and will spray under high temperature, even causing personal injury.
9. The equipment adjustment parameters must be reset after the new heat conduction medium is filled.
The above are technical maintenance and use matters. If you have other information needs about the equipment, you can leave a message to us, or even send an email to sales@lneya.com
関連推奨品
-
真空ポンプ温度制御システムの使用における誤解
1852真空ポンプの温度制御システムを使用する場合、正しい操作方法のみが装置の正常で安定した動作を保証することができます。もし間違った操作方法が多ければ、装置の正常な使用に直接影響します。
詳細を見る -
公式発表!2018年API Chinaが正式にキックオフ
1981Official announcement! 2018 API China On October 17th, the Nanjing International Expo Center officially kicked off~ Wuxi Guanya carries popular products: Refrigeration heating temperature control system, TCU, refrigeration heating circulator and o...
詳細を見る -
水冷式冷凍機の長所と短所
2093LNEYAが製造する水冷式工業用チラーは、冷水を供給する冷凍装置です。本日は、水冷式チラーの分類、メリット、デメリットについて説明する。水冷式冷凍機の構成1....
詳細を見る -
油圧による冷凍機コンプレッサーの故障
1947冷凍制御系統に油圧がない場合、オイルポンプ配管系統の接続部に油漏れや詰まりがないか確認する。接続部が緩んでいる場合は、接続部を締める。閉塞している場合は、オイル配管を...
詳細を見る
工業冷水機製造商 LNEYA Taiwan