油圧による冷凍機コンプレッサーの故障
If there is no oil pressure in the refrigeration control system, check the oil pump piping system connection for oil leakage or blockage. If the connection is loose, the joint should be tightened. If it is blocked, the oil pipeline should be cleared. Then check whether the compressor of the refrigeration control system is too large due to the opening of the oil pressure regulating valve or the valve core is detached. If the hydraulic pressure regulating valve of the refrigeration control system is improperly adjusted, adjust the oil pressure regulating valve and adjust the oil pressure to the required value. If the valve core is detached, the valve core should be reinstalled and tightened. If there is too little oil in the crankcase of the refrigeration control system or there is refrigerant, the oil pump will not enter the oil. If the oil is too small, it should be timely. Refueling, if it is the latter, stop in time to eliminate the refrigerant. Pay attention to the oil pump. If the oil pump wears out seriously, the clearance will be too large, causing the oil pressure to not come up. In this case, the oil pump should be repaired and replaced directly if the fault is serious. The timely cooling control system checks whether the connecting rod bearing bush, the main bearing bush, the connecting rod small head bushing and the piston pin have been seriously worn, and the relevant parts are replaced in time, and the rear end cover gasket of the crankcase is misplaced, blocking the intake of the oil pump. The oil passage should be disassembled and the position of the gasket should be re-fixed.
Of course, the oil temperature of the refrigeration control system needs to be in the normal range. If the oil temperature is too high, it is necessary to check in time whether the shaft and the tile are improperly assembled, and the clearance is too small. The size of the shaft and tile assembly clearance should be adjusted so that the clearance meets the standard requirements. It is. Next, check the lubricating oil for impurities, which will cause the bearing bush to be pulled. For this, the brushed bushing should be flattened and replaced with new oil. If the tile is severely pulled, replace the new tile. Then check that the shaft seal friction ring is installed too tightly or the friction ring is pulled, and the shaft seal friction ring is re-adjusted in time. If the friction ring is severely pulled, replace the new friction ring. If the suction and exhaust temperatures of the compressor of the refrigeration control system are too high, the system’s liquid supply valve should be properly adjusted to restore the suction and exhaust temperatures to normal.
Overall, the refrigeration control system compressor failure solution is not as simple as imagined, so we need our operators to know more about our refrigeration control system and have enough knowledge to face these faults.
関連推奨品
-
原薬製造における温度サイクル制御加熱・冷却の重要性
2353中国は世界最大の原薬供給市場となっている。外資系メーカーが必要とする原薬や中間体のほとんどは、わが国で購入されている。そのほとんどの製剤製品の医薬品外注工程、製造工程...
詳細を見る -
空冷式産業用チラーの特性分析
1736Industrial air-cooled chillers are generally integral machines, that is, evaporator, compressor and condenser are made together. For a slightly high-power air-cooled industrial chiller, the heat dissipation of the condenser cooling fan needs to be...
詳細を見る -
ICテストにおける温度の重要性
3087すべての集積回路(IC)は、それが販売され、製品を構築するために使用される前に、2つのタイプのテストを通過します:1つ目は、ウェハテストと呼ばれ、2つ目は、最終テストと呼ばれています。ウェハー・テストと呼ばれるものと、ファイナル・テストと呼ばれるものである。
詳細を見る -
低温循環装置の霜付きを解決するには?
2473低温循環装置フロストの不具合は、主にコンプレッサーの戻り空気温度が低すぎるためで、低温循環装置ではスロットルバルブの液体冷媒供給が正常な状態であることが考えられる。
詳細を見る
工業冷水機製造商 LNEYA Taiwan