駅全体を検索


ブログ

關於 LNEYA 產品選用、優勢及冰水機產業的相關資訊。

グリコールチラーの漏れ点検の注意点

ニュース 26560

The main points about checking leakage of glycol chiller
During the operation of the glycol chiller, it is critical that the refrigeration system does not leak.

Precautions for Leakage Inspection of Glycol Chiller(images 1)


In order to avoid the leakage of refrigerant and other gases from the glycol chiller, the inspection of the welding quality is more important. First check whether the sealing performance of the weld is good. After adding refrigerant or nitrogen and allowing it to stabilize for a certain period of time, it can be tested with soapy water or other methods. When the refrigeration cycle is in operation, the welds should not be cracked due to vibration, the pipes should not be blocked by debris during welding, and should not enter moisture due to improper operation. When the refrigeration cycle is working, the surface of the welded parts should be clean and clean. No oil stains.

The common leakage points of glycol chillers are evaporator leakage, refrigeration cycle connection leakage, refrigeration cycle valve leakage, compressor pipeline leakage, capillary vibration wear, four-way reversing valve leakage, etc. Common inspections Leakage methods are commonly used in the production and maintenance of refrigeration cycles: visual leak detection, pressure leak detection, instrument leak detection, vacuum leak detection, etc. The user can solve the leakage points one by one.

The fault of leak detection of glycol chiller is relatively common. Therefore, when choosing, it is recommended to choose a fully closed loop piping system and valve parts to choose branded accessories. The evaporator uses a high-power plate heat exchanger, which is small in size, high in efficiency, fast in cooling, safe and reliable, and is used for rapid liquid cooling. It is widely used in petrochemical, medical, pharmaceutical, biochemical, freeze-drying, pharmaceutical, military and other high-tech industries.


前の記事 次だ:

関連推奨品

  • ICテストにおける温度の重要性

    3087

    すべての集積回路(IC)は、それが販売され、製品を構築するために使用される前に、2つのタイプのテストを通過します:1つ目は、ウェハテストと呼ばれ、2つ目は、最終テストと呼ばれています。ウェハー・テストと呼ばれるものと、ファイナル・テストと呼ばれるものである。

    詳細を見る
  • Suitable Freezer Manufacturer

    1690

    For enterprise users, choosing a suitable freezer manufacturer is very important and must be carefully treated. Wuxi Guanya Refrigeration technology co., Ltd, as a professional freezer manufacturer, is committed to producing all kinds of low tempe...

    詳細を見る
もっと拡大する!