Heat transfer oil for cooling and heating temperature control systems in the chemical and pharmaceut
The cooling and heating temperature control system, also known as a high and low temperature circulator or dynamic temperature control system, is a temperature control equipment used in the pharmaceutical and chemical industry to provide cold and heat sources for supporting reaction kettles. The LNEYA cooling and heating temperature control system uses heat transfer oil as the heat transfer medium. Depending on the temperature range and model of the equipment, different types of heat transfer oil can be selected.
1. Application note: Heat transfer oil is divided into different models based on different temperature ranges. It is recommended to choose the appropriate heat transfer oil according to the temperature range of the equipment model. Due to differences in equipment configuration, the heat transfer oil consumption of different refrigeration heating and temperature control thermostats varies. If it is a fully enclosed circulation pipeline, there is no water vapor or oil mist, and the amount used will be less than that of an open refrigeration heating and temperature control thermostat.
2. Quality analysis of heat transfer oil: The heat transfer oil in the cooling and heating temperature control system is generally analyzed from four aspects: viscosity, flash point, acid value, and residual carbon. Generally speaking, if the quality of the heat transfer oil in the refrigeration and heating temperature control thermostat changes, its viscosity will change. A change in acid value indicates that the heat transfer oil is contaminated or oxidized, and operators need to pay attention to it and replace it in a timely manner. If the heat transfer oil does not corrode, check the residual carbon value. Once it reaches the average value, it should be taken seriously. If these four data items do not exceed the range of changes, it indicates that the quality of the heat transfer oil in the refrigeration heating temperature control thermostat is good and can still operate normally. If one item is abnormal, it is necessary to consider taking corresponding measures and replacing it with a new heat transfer oil in a timely manner.
3. Precautions for use: The placement environment of heat transfer oil and refrigeration heating temperature control thermostats should be in a well ventilated and reliable environment. Although the boiling point of heat transfer oil is high, it is still necessary to avoid open flames. If the heat transfer oil leaks, it can cause accidents in contact with open flames, so open flames should be kept away. At the same time, it is necessary to be careful not to place it in the hot gas flame area to avoid ignition sources.
関連推奨品
-
LNEYA、「日本共産党」と闘い無事生産再開
2407日本共産党は2020年の新しい年に霞をかけたが、すべてが回復する瞬間は決してないわけではない。現在、全国の多くの企業にとって、経営の重圧と肩の荷は非常に重い。しかし、LNEYA ...
詳細を見る -
冷暖房温度制御システムにおける温度変化のシミュレーション制御
1676工業用冷却・加熱温度制御システムは、製薬・化学工業における反応釜の冷却・加熱工程で使用される温度制御装置です。ルネヤの装置の特徴は?
詳細を見る -
How to troubleshoot the failure of the material aging test chiller?
2178Regular maintenance work for the material aging test chiller, and troubleshooting is also very important. 1. Exhaust at double high pressure, heat dissipation may be problematic. When it is detected that the high and low pressure of the system are...
詳細を見る -
製薬研究所では、遠心ポンプと容積式ポンプのどちらを選択するのですか?
1891製薬研究室では、様々な冷凍機器がより多く使用され、その後、より一般的な機器として、ポンプ、主に遠心ポンプ、容積式ポンプが使用されます。その後、ユーザーの友人は、それらの性能についてより良い理解を持っている必要があります...
詳細を見る
工業冷水機製造商 LNEYA Taiwan