研究室専用チラーの圧力説明
について laboratory-specific chiller is one of the more popular equipments in the mechanical equipment industry. For this reason, the relevant pressure instructions have been specially compiled to help you better understand the laboratory-specific chiller.
The reference value of the test chamber-specific chiller and the pressure resistance of the piping system components refers to the design given pressure related to the mechanical strength of the pipeline components. The nominal pressure is generally expressed by PN. Nominal pressure—the compressive strength of the product at the reference temperature, expressed in PN, unit: MPa, reference temperature: different materials, the reference temperature is also different, for example, the steel reference temperature is 250 ° C, the nominal pressure is 1.0 Mpa, Recorded as: PN 1.0 Mpa.
The working pressure of the special chiller in the laboratory refers to the large pressure specified by the high working temperature of the pipeline conveying medium for the operation safety of the pipeline system. The working pressure is generally expressed by Pt.
The design chiller design pressure of the laboratory refers to the large instantaneous pressure of the water supply pipe system acting on the inner wall of the pipe. The sum of the working pressure and the residual water hammer pressure is generally used. The design pressure is generally expressed by Pe. The test pressure refers to the pressure to be achieved by the pipeline, container or equipment under the pressure resistance and air tightness test. The test pressure is generally expressed by Ps.
The nominal chiller pressure of the laboratory is a nominal pressure artificially specified for the convenience of design, manufacture and use. The unit of this nominal pressure is actually the pressure, and the pressure is the common name of Chinese. The unit is “Pa”. Not “N”. The nominal pressure of a pressure vessel refers to the nominal pressure of the pressure vessel flange. The nominal pressure of the pressure vessel flange is generally divided into seven grades, namely 0.25, 0.60, 1.00, 1.60, 2.50, 4.00, 6.40 MPa.
In general, the pressure can be divided into: test pressure > nominal pressure > design pressure > working pressure, so, everyone understands?
関連推奨品
-
The Refrigeration Principle of Heating Cooling Circulator
2015Heating cooling circulator is the use of limited refrigerant in the closed refrigeration system, repeatedly refrigerant compression, condensation, expansion, evaporation, constantly in the evaporator heat absorption vaporization, cooling. The heat...
詳細を見る -
反応炉の自動温度制御システムの水冷チラーの緊急時用
1729In the pharmaceutical and chemical production, the automatic temperature control system of the reactor is widely visible. In order to ensure the safe production of the enterprise, what should users pay attention to when facing unexpected situatio...
詳細を見る -
高温・低温テスターの温度制御範囲と精度
339部品試験に使用される高温低温試験機の熱媒油の温度制御精度はプラスマイナス0.5℃であり、電子部品の温度制御遅れの問題を解決する。主な利点...
詳細を見る -
水冷式チラーと空冷式チラーの選択方法
2038現在、工業用冷水機は、石油化学工業、プラスチック工業、電子工業、真空コーティングなど、さまざまな産業に応用されている。しかし、工業用冷水機を購入する際、多くのエンタ...
詳細を見る