TCU温度制御モデルの選択と技術パラメータの説明
TCU temperature control is also a two-cycle unit single-fluid temperature control system. When selecting the model, it is very important for the whole temperature control reaction. Only the appropriate reaction system is used to exotherm and absorb the whole reaction process. The heat responds to the entire control, so the choice of model is very important.
温度制御ユニット temperature control model: SR-10
Model SR-10 with operating temperature range of -120~200°C, suitable reaction vessel is 50L-250L, circulating pump flow pressure is controlled at 3m3/h1.5bar, circulating pump can not be adjusted, auxiliary heating power is 10KW, pre- The interface of the heat exchange module is DN25, and electric power, steam, hot oil, hot water, cooling water, chilled water and ultra-low temperature medium can be used as primary energy.
TCU temperature control model: SR-20
Model SR-20 with operating temperature range of -120~200°C, suitable reaction vessel is 100L-500L, circulating pump flow pressure is controlled at 2.4~6.6m3/h1.5bar, circulating pump control can be adjusted by frequency or fixed speed. The auxiliary heating power is 20KW, and the interface of the preheating heat exchange module is DN32.
TCU temperature control model: SR-38
Model SR-38 with operating temperature range of -120~200°C, suitable reaction vessel is 300L-1000L, circulating pump flow pressure is controlled at 5~12m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 38KW, and the interface of the preheating heat exchange module is DN40.
TCU temperature control model: SR-60
Model SR-60 with operating temperature range of -120~200°C, suitable reaction vessel is 500L-2000L, circulating pump flow pressure is controlled at 11~25m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 60KW, and the interface of the preheating heat exchange module is DN65.
TCU temperature control model: SR-95
Model SR-95 with operating temperature range of -120~200°C, suitable reaction vessel is 1000L-5000L, circulating pump flow pressure is controlled at 20~50m3/h2.5bar, circulating pump control can be adjusted by frequency or fixed speed, auxiliary The heating power is 95KW, and the interface of the preheating heat exchange module is DN80.
In addition, the energy conversion of TCU temperature control is carried out by heat exchanger and electric heating. In the temperature control mode selection, the material temperature control and jacket temperature control can be freely selected, and the material temperature control accuracy is ±1 °C. Inch / inch color touch screen. The temperature control of the whole TCU is a fully enclosed system. There is no oil mist at high temperature and no moisture in the air at low temperature. The TCU temperature control system does not increase the fluid pressure due to high temperature during operation, and automatically supplements the heat transfer medium at low temperature.
関連推奨品
-
低温循環装置の霜付きを解決するには?
2473低温循環装置フロストの不具合は、主にコンプレッサーの戻り空気温度が低すぎるためで、低温循環装置ではスロットルバルブの液体冷媒供給が正常な状態であることが考えられる。
詳細を見る -
LNEYA新エネルギー電気自動車試験温度制御冷暖房ソリューション
2214With the gradual electrification of the automotive industry, the new energy vehicle market has entered a stage of rapid development. The battery is the heart of new energy vehicles, and charging is the source to ensure their operation. Therefore, ...
詳細を見る -
超低温チラーの晶析技術の石油産業への応用
1810本稿では、主に工業用冷凍機の冷凍技術晶析技術の石油産業への応用と冷凍晶析の原理について紹介する。現在、凍結晶析を利用した分離方法は、石油業界で広く利用されている。
詳細を見る -
温冷一体型コントロールマシンの設置はどうする?
2318熱電対の熱慣性がメーターの指示値を測定温度に遅らせる原因となるため、この影響は特に高速測定を行う場合に顕著となる。そのため、より薄い熱電極を持つ熱電対...
詳細を見る