The Advantages Of The Industrial Chiller For Cascade Cryogenic Refrigeration System
Cascade cryogenic refrigeration system is a low-temperature refrigeration system which uses more than two refrigerants and combines them with heat exchangers (condenser evaporators) in more than two systems. For binary cascade refrigeration system chiller, it consists of two separate refrigeration systems. One is the high temperature system, the other is the low temperature system. The cryogenic system is used to cool the environmental laboratory, while the high-temperature system is used to cool the exhaust gas of the cryogenic system and condensate it at a lower temperature. This also achieves the purpose of reducing compression ratio and improving gas transmission coefficient.
The advantages of the industrial chiller for cascade 極低温冷凍システム are the use of medium-pressure refrigerants suitable for high-temperature systems and high-pressure refrigerants suitable for low-temperature systems. The specific capacity of high pressure refrigerant gas at low temperature is much smaller than that of medium pressure refrigerant. Therefore, the refrigeration capacity of the same type of compressor for cascade refrigeration is several times larger than that of two-stage compression refrigeration at low temperature. The use of cascade refrigeration system water cooler can save a lot of investment and building area. Moreover, the high-pressure refrigerant operates at a low temperature with an inhalation pressure greater than or close to one atmosphere, and it does not often infiltrate into the system like a two-stage cryogenic system.
The cascade refrigeration system can be used for industrial water chillers, except that the user’s requirement varies greatly and the ambient temperature is above – 55 C. At present, there are more and more cold sources using cascade refrigeration system as cryogenic experimental equipment.
関連推奨品
-
ルネヤの極低温産業用冷凍機を導入されるお客様へ注意事項
2198ひとつ。低温工業用冷凍機を設置する際には、いくつかの設置条件に注意する必要がある。1.低温の産業スリラーは横の位置に直接取付けられるべきですそれを逆さまに取付けなかったりまたは dia...
詳細を見る -
半導体恒温装置の価格をどう選ぶか?
2017Now, it can be said that most of the industrial production of various types require a semiconductor thermostat system to provide professional refrigeration, and an efficient semiconductor constant temperature system can provide great help for vari...
詳細を見る -
自動車用クーラント(ELC)テストの利点とクーラントコンディショナーシステムの紹介
2109The cooling system is one of the main components of the engine. Its main function is to protect the engine from corrosion, pitting, corrosion and overheating. It is compatible with different engine materials and lubricates the engine cooling pump....
詳細を見る -
What should be paid attention to when placing the thermostat system?
1810There are certain differences in the size and performance of the high and low temperature thermostat systems produced by different manufacturers. The user needs to pay attention to how it is placed when placing it after purchase, otherwise it will...
詳細を見る
工業冷水機製造商 LNEYA Taiwan











