The user can arrange the operator to learn about the daily maintenance knowledge of the 12HP (8.9kW) low temperature chiller after purchase. It can not only improve the company’s product quality, improve production efficiency, but also extend the service life of the 12HP (8.9kW) low-temperature chiller by using the knowledge learned.
1. In the initial operation of the 12HP (8.9kW) low-temperature chiller, the oil level, oil return and oil cleanliness of the compressor should be observed frequently. If the oil is dirty or the oil level drops, it should be replaced or added in time to avoid poor lubrication and affect refrigeration. machine is running.
2. For air-cooled: the air-cooler should be cleaned frequently to maintain a good heat exchange state, and the condenser should be checked frequently for scaling problems, and the scale should be removed in time.
3. For water-cooled: Always check the turbidity of the cooling water, if the cooling water is too dirty, it needs to be replaced, whether the water pump is working normally, whether the valve switch is effective, whether the cooling water tower and the fan are normal.
4. For the air-cooled evaporator: it is necessary to check the defrosting situation frequently. Whether the defrosting is timely and effective will affect the cooling effect and cause the refrigeration system to return to liquid.
5. Always observe the compressor running status of the 12HP (8.9kW) low-temperature chiller, check its exhaust temperature, and pay special attention to the running status of the system when operating in a seasonal change, and adjust the liquid supply and condensing temperature of the system in time.
6. Carefully listen to the running sound of the compressor, cooling tower, water pump or condenser fan, find out and deal with it in time, and check the vibration of the compressor, exhaust pipe and water pump at the same time.
7. After 30 days of operation, the refrigerating oil and drying filter should be replaced once, and after half a year of operation (depending on the actual situation). For systems with higher cleanliness, the refrigeration oil and filter drier should be replaced after six months of operation.
Our LNEYA is a professional fabricante de refrigeradores, our customers are located in Europe, America and Southeast Asia. For the 12HP (8.9kW) low temperature chiller, you can contact us if you have any questions.
Recomendações relacionadas
-
Área de aplicação do sistema de controlo de refrigeração e arrefecimento a alta temperatura
1794O sistema de controlo de refrigeração e arrefecimento a alta temperatura é utilizado para suportar reactores de vidro, evaporadores rotativos, tanques de fermentação e calorímetros; amplamente utilizado em petróleo, química, metalurgia, bioquímica, física, testes e...
Ver detalhes -
Quais são as caraterísticas da pressão dos refrigeradores de água industriais
2222Os refrigeradores de água industriais são um dos equipamentos mais populares na indústria de máquinas e equipamentos. Por esta razão, o editor do LNEYA compilou especialmente instruções de pressão relevantes para ajudar todos a entender melhor os refrigeradores de água industriais...
Ver detalhes -
Detailed Operating Instructions of Industrial Chiller
2545The installation procedures of water chiller include: 1. During installation, please check whether the machine is damaged and select a suitable place for installation and future maintenance. The site for installing the unit must be the floor o...
Ver detalhes -
Quais são as funções da câmara de ensaio de envelhecimento a alta e baixa temperatura para a produção de pastilhas?
1977Atualmente, a indústria de produção de bolachas com chip está a enfrentar desafios e mudanças sem precedentes. Para além da tecnologia, a produção sempre foi uma preocupação na indústria. Todos nós sabemos que o nascimento de um chip requer muitos processos, e um bom chip...
Ver detalhes
工業冷水機製造商 LNEYA Taiwan