A que é que se deve prestar atenção quando se utiliza o banho de óleo para arrefecimento e aquecimento?
In the high and low temperature control, cooling and heating oil bath is one of the more important equipment. What aspects do users need to pay attention to when running the device?
O cooling and heating oil bath equipment should be kept clean and dry. It is strictly forbidden to heat the solution in the stainless steel pot without burning the heater to avoid burning the heater. If the measured temperature differs greatly from the actual temperature, it is usually obtained with the wrong sensor. Place the sensor in boiling water and the meter should display 100 °C. Otherwise check that the sensor is consistent with the meter input type.
O cooling and heating oil bath meter indicates that the HHH is the measured value that is outside the meter range or the thermocouple is broken. It indicates that the LLL is the measured value lower than the lower limit of the meter range or the thermocouple is reversed. The instrument of the cooling and heating oil bath shows normal, the temperature suddenly loses control, and the external load should be checked for short circuit or open circuit.
When the cooling and heating oil bath is not working, the power should be cut off. To ensure safety, please connect the ground wire during use. The electric power and the heat taken away from the load by the refrigerant need to be removed from the radiator at the front hood. The front hood is filled with dust and cotton wool, which will prevent the heat from being dissipated and the cooling effect will be greatly reduced. Generally, the decrease in cooling capacity under normal use conditions is caused by poor ventilation or high ambient temperature.
When the cooling and heating oil bath is in operation, it is necessary to understand these points of use and then operate better.
Recomendações relacionadas
-
Why is there air in the reactor temperature control system?
1919The impurity gas in the reactor temperature control system is to increase the condensing pressure of the refrigeration system, thereby increasing the condensing temperature, increasing the exhaust temperature of the compressor, increasing the powe...
Ver detalhes -
Instruções de cablagem da bobina do ventilador do congelador industrial de baixa temperatura
1977The electric two-way valve red line of the low-temperature industrial freezer is 220V hot wire (L) directly connected to the thermostat fire line interface, the blue line is zero line (N), the coil, the two-way valve, the thermostat is connected i...
Ver detalhes -
Etapas da operação de descarga do refrigerador industrial no sistema de refrigeração de amoníaco
2027The rubber hose used to connect the outlet valve joint causes one end to be inserted into the water of the water container. When the ammonia in the mixed gas is cooled into ammonia liquid, the bottom of the air separator will frost. At this time, ...
Ver detalhes -
Seleção do óleo de transferência de calor para o sistema de refrigeração e aquecimento do reator
2215Na indústria química, o reator é um recipiente muito utilizado e o controlo da temperatura é a principal quantidade a controlar. O equipamento do ciclo de aquecimento e refrigeração do reator é um fator importante para garantir a qualidade do produto. O re...
Ver detalhes
工業冷水機製造商 LNEYA Taiwan