Design and Test Technology of High Temperature Environmental Chamber Sales
1. Temperature selection
(1) The climatic zones of the region; Whether the product is exposed to the solar radiation environment near the heating device; Surrounding air, solar radiation and ways of heat transfer from heating devices to products; The actual technical state of the product (open or shaded).
(2)Use similar product temperature. Similar products refer to those with similar USES, performance and installation locations, such as upgrading products
2. The conditions of environmental chamber sales
(1) High-temperature storage
Thermostatic storage: after the sample reaches temperature stability (the temperature of internal components, components, modules, components, etc., also reaches stability) in the high-temperature environment, it can be maintained for at least 2 hours, and the longest can be 48 hours. If the storage time is over 48 hours, the temperature stability time will be included.
Cyclic storage: at least 7 cycles (24h for one cycle). If the key material or high temperature sensitive material is affected by high temperature environment, the cycle number should be increased appropriately.
(2) Hot operation in environmental chamber sales
Thermostatic work: after samples reached the stable in high temperature working environment(judgment methods: the differences of the internal heat of samples of the largest feature or key components should be less than 2 ℃ per hour , If the temperature of the internal element (part) cannot be measured, the temperature time shall be determined according to the thermal analysis to ensure that the temperature of the whole sample is stable)keep it at least 2 h, and then let the sample work, and make it on the specified working temperature to achieve stability, began to test the functionality and performance. After the test is completed, the sample will stop working and the air temperature in the box will be adjusted to the standard atmospheric conditions. After reaching the stability under the standard atmospheric conditions, the overall appearance, function and performance will be tested.
3. Temperature monitoring in environmental chambers
When monitoring the test temperature, the position of the temperature sensor should ensure that the influence of thermal diffusion is negligible, and pay attention to avoid the influence of thermal radiation.
Recomendações relacionadas
-
Precauções para o sistema de arrefecimento do chiller no ensaio de funcionamento a baixa temperatura
2331Existem certas diferenças no método de utilização, função, estrutura, etc. dos diferentes tipos de sistemas de arrefecimento do chiller para o teste de funcionamento a baixa temperatura. O refrigerador do teste de funcionamento a baixa temperatura industrial requer a geração de calor...
Ver detalhes -
Como eliminar o alarme de alta pressão do congelador industrial de temperatura ultrabaixa?
1710Durante a utilização, se uma falha não for resolvida a tempo, afectará a utilização do congelador industrial de temperatura ultra baixa. Como resolver o problema do alarme de alta pressão? Se o congelador industrial de temperatura ultrabaixa arrefecido a água apresentar um alarme de alta pressão...
Ver detalhes -
Descrição do princípio de refrigeração no controlo da temperatura de bolachas semicondutoras
2416No funcionamento do sistema de refrigeração para controlo da temperatura de bolachas semicondutoras, é utilizada uma transição de estado de um determinado fluido de trabalho e o calor necessário Q0 é extraído da fonte de calor de uma temperatura mais baixa, e o calor Qk é...
Ver detalhes -
A existência de destilação e controlo da temperatura durante a destilação - controlo dinâmico da temperatura Sundi
1900A destilação existe em indústrias como a biofarmacêutica e a petroquímica. A destilação laboratorial inclui a destilação sob vácuo, a destilação de percurso curto, a destilação de película fina, a destilação a vapor, a destilação por lotes, a destilação azeotrópica...
Ver detalhes