Como resolver o problema do fraco desempenho de arrefecimento do sistema de circulação do óleo de transferência de calor?
Some heat-conducting oil circulation systems will not be as good as before after 3 months of use. At this time, it is recommended to contact the professional after-sales department to check the user’s power supply and whether the equipment is normal. The test heat conduction oil circulation system is set to cool operation, and the working pressure is 4.5kg/cm2. Considering that the variable frequency heat transfer oil circulation system uses the electronic expansion valve to throttle, it is not accurate to judge the fault only by the working pressure. Therefore, the outdoor working current is measured again. The measurement finds that the working current is only 10.5A, which is much smaller than the rated value, and the fault is determined as “ Lack of refrigerant.”
Then, first find out the refrigerant leakage part of the heat transfer oil circulation system. Try to open the mechanism heat, use the washing spirit liquid to coat the joints for leak detection, and find that the joint is not tightened, which is the cause of refrigerant leakage. After tightening, check the leak again to make sure the pipeline is intact and then charge the system with refrigerant.
The heat transfer oil circulation system uses the “constant flow charging method”. In order to ensure the accuracy of the refrigerant charge, the exhaust pipe temperature sensor is first suspended. After starting up, use the ammeter to measure the current on the outdoor power line of the heat transfer oil circulation system. As the refrigerant replenishment increases, the current will gradually increase. When the rated current value reaches 12A (the 70-type inverter cabinet is 16A), the refrigeration The dosage of the agent is appropriate. This method is often used during home repairs.
If the heat transfer oil circulation system is overhauled or the leak is too large, and the refrigerant has leaked out in the system for a long time, the refrigerant can be charged by the quantitative method. First, the system is evacuated, and vacuuming or external air evacuation can be used. Then, the system is filled with refrigerant according to the standard. If the external air is emptied, it should be slightly less than the standard amount and in the cold state. These are the reasons why after a few months of use, suddenly become uncooled or poorly cooled.
LNEYA provides professional heat transfer oil circulation system, which is mainly engaged in professional brand equipment, with safe and reliable quality. If you need it, please come and purchase it.
Recomendações relacionadas
-
Quais são os sistemas de teste de potência para baterias de automóveis de energia nova?
1951The LNEYA power battery system is tested for battery testing of new energy vehicles, but modern new energy vehicles have many types of batteries. So what are the characteristics? The ternary lithium battery refers to a lithium battery in which the...
Ver detalhes -
Como é que o equipamento de circulação de refrigeração e aquecimento controla a temperatura do vidro da camisa?
1704O equipamento de circulação de arrefecimento e aquecimento está frequentemente equipado com uma chaleira de reação para controlo da temperatura, por isso, como ligar e controlar a temperatura? 1. Interface de entrada e saída da camisa circular Utilizamos principalmente interfaces de flange para a entrada ...
Ver detalhes -
Quais são os locais a escolher para os refrigerados?
2276Atualmente, com o desenvolvimento da ciência e da tecnologia, muitos clientes centram-se na utilização de temperaturas altas e baixas para melhorar a qualidade dos produtos e reduzir o seu custo. Então, quais são os lugares para prestar atenção ao escolher um modelo? O homem...
Ver detalhes -
Sistema de controlo integrado do dispositivo de ciclo de alta e baixa temperatura Dispositivos de utilização da série ZLF
2048With the development of society, the chemical industry has been further developed, and the temperature system control of the reactor has been strengthened, so as to ensure that the monitoring environment is in a good state, to ensure that the temp...
Ver detalhes