Detalhes do dispositivo de proteção do dispositivo de controlo da temperatura do fluido de circulação
The circulating pump overload protection function is to cut off the main power of the circulating pump when the circulating liquid temperature adjustment device is too large. Press the green button when resetting; the red button is the stop button, which is used during the test. When frequent protection, please check whether the voltage is under voltage (undervoltage is less than 15%, the power protector is not working), undervoltage is increased into current, forming protection. At this time, a Phillips screwdriver can be used to adjust according to the “△” direction. Current.
Different circulating fluid temperature adjustment devices are equipped with different high and low voltage protectors. The high and low pressure protectors will protect the compressor with reference to the suction and exhaust pressure of the compressor to ensure the normal operation and operating life of the compressor. The high and low voltage protectors are divided into mechanical and electronic high and low voltage protectors. When the high and low voltage protectors are protected, manual reset is required. Press the red highlight button to reset. When the high and low voltage protectors generate protection, manual reset is required. Push the red arrow to reset. The electronic high and low voltage protector is automatically reset.
The circulating fluid temperature adjustment system provides a lot of accessories for equipment protection to ensure the safety and stability of the equipment. The over temperature protection has an independent high temperature temperature limit switch, which can set a relatively large temperature value through this temperature switch (please note) Meet the relatively large operating temperature range of the equipment and the temperature range of the heat transfer oil).
Inspiratory temperature protection with independent compressor suction temperature protector to protect the compressor from excessive suction temperature, ensure that it is within 65 °C (non-recycling liquid temperature adjustment device manufacturer authorization, do not modify, will directly affect the compressor Cooling capacity).
Circulating fluid temperature adjustment device The oil pressure difference protector is generally applied in large equipment. Depending on the equipment, the oil pressure difference protector is different. Press the upper ink green button when resetting. Other types of oil pressure difference protectors are similar. The reset button can be reset by itself. Other protections of the circulating fluid temperature adjustment device include phase protection, phase loss protection, overvoltage and undervoltage protection, leakage protection, and water shutoff protection.
The protection devices of different circulating liquid temperature adjustment devices are different. No matter what brand, the safety devices are more important. We need to pay attention to them. We must carefully check before purchasing to ensure the operation of the equipment.
Recomendações relacionadas
-
Escopo de aplicação do resfriador de precisão LNEYA
2152The main application industries of LNEYA precision chiller include plastic industry, electronic industry, electroplating industry, medicine industry, food industry, vacuum coating industry and so on. These industries are the main application indus...
Ver detalhes -
Precauções de manutenção do evaporador do frigorífico industrial de alta potência
2181Os frigoríficos industriais de alta potência são utilizados no processamento industrial de frio. Os evaporadores dos frigoríficos industriais de alta potência são um dos componentes mais importantes e um dos factores que afectam o efeito de arrefecimento dos frigoríficos industriais de alta potência...
Ver detalhes -
Titanium reactor temperature control in daily chemical, pharmaceutical and chemical industries
2121The advantages and trends of titanium reactors in the daily chemical and pharmaceutical industries, titanium reactors will play a huge advantage in the future. Reaction equipment used to complete processes such as sulfonation, nitration, hydrogen...
Ver detalhes -
Instruções de preparação da série TES-5 dedicada ao teste de chips
1882A série TES-5 para teste de chips é utilizada para testes de componentes electrónicos. A forma de detetar com precisão o chip é muito importante. Então, quanto é que sabe sobre a preparação do teste para a série TES-5 para teste de chips? Antes de iniciar o teste da série TES-5...
Ver detalhes
工業冷水機製造商 LNEYA Taiwan