Sistema de arrefecimento do grupo motopropulsor da transmissão com evaporador
The evaporator is one of the four major components of the refrigeration system, and it is the ultimate embodiment of the refrigeration effect and efficiency. The evaporator is generally designed and equipped by the transmission powertrain cooling system manufacturer, and the user does not need to choose. However, in order to better maintain the refrigeration system and ensure its operation, the following points should be noted:
1. The influence of liquid level on evaporation temperature. Due to the height of the refrigerant liquid column, the evaporation temperature at the bottom of the flooded evaporator is higher than the evaporation temperature of the liquid surface. The evaporation temperature of different refrigerants at different liquid levels is affected differently by the height of the static liquid. Regardless of the refrigerant, the lower the evaporation temperature of the liquid surface, the greater the influence of the hydrostatic height on the evaporation temperature. Therefore, only when the evaporation pressure is high, the influence of the hydrostatic height on the evaporation temperature can be ignored. When the evaporation temperature is low, it cannot be ignored. In other words, it becomes uneconomical to use a flooded evaporator at this time.
2. The possibility of freezing of the refrigerant. If the evaporation temperature is lower than the freezing temperature of the refrigerant, the refrigerant may freeze. When water is used as the refrigerant, theoretically, the temperature of the inner wall of the tube can be as low as possible. However, for the sake of simplicity, the temperature of the inner wall of the pipe at the outlet end of the latter process is usually kept above. For the case of brine as the refrigerant, according to the same principle, the temperature of the inner wall of the tube should be higher than the freezing temperature of the refrigerant.
3. The pressure loss of the refrigerant in the evaporator. When the refrigerant flows through the evaporator, pressure loss is caused, which will inevitably make the pressure p2 of the refrigerant at the outlet of the evaporator be lower than the pressure p1 at the inlet, thereby reducing the suction pressure of the compressor, resulting in a decline in the refrigeration capacity.
4. According to different models, the choice of evaporator is different. For example, the cooling system of the box-type small transmission powertrain uses a water tank coil type evaporator; the open type small transmission powertrain cooling system and the small screw type For transmission powertrain cooling system, shell and tube evaporator is used; for acid and alkali resistant transmission powertrain cooling system, titanium tube evaporator or stainless steel plate exchanger can be selected.
There are many options for the cooling system of the small transmission powertrain. Of course, it can be customized according to the needs of users.
Recomendações relacionadas
-
A que devo prestar atenção ao adicionar refrigerante a um chiller arrefecido a água?
2157In our life, we believe that everyone is very familiar with refrigeration. In the central air conditioning and industrial production process cooling industry, small water-cooled chillers is more common. This unit is composed of a compressor in the...
Ver detalhes -
Celebrar o dia de Ano Novo e dar as boas-vindas ao Ano Novo
2287Quando os sinos ecoam no céu claro da noite,Quando o calendário vira para uma nova página,Estamos prestes a dar início a um novo ano.Obrigado pela colheita deste anoVamos ter uma experiência preciosa no nosso crescimentoHá sempre uma recompensa para o suorEste ano, nós...
Ver detalhes -
SUNDI Cooling And Heating System-R & D testing of organic synthetic materials and fine chemicals
2221LNEYA's customer is a research institute engaged in the research, development and production of high-performance, environmentally-friendly new organic materials and fine chemicals.The adhesives produced by customers can be used in integrated circu...
Ver detalhes -
Como resolver o problema do congelamento do dispositivo de circulação a baixa temperatura?
2473A falha do congelamento do dispositivo de circulação a baixa temperatura deve-se principalmente ao facto de a temperatura do ar de retorno do compressor ser demasiado baixa, o que pode ser o facto de o fornecimento de refrigerante líquido da válvula de estrangulamento estar num estado normal na circulação a baixa temperatura...
Ver detalhes