Instruções de controlo da temperatura da câmara de ensaio de mudança rápida de temperatura
The selection of the humidity range of the rapid temperature change test chamber should be noted that the corresponding temperature range should be indicated after the humidity index or the dew point temperature should be given. Because relative humidity is directly related to temperature, for the same moisture content, the higher the temperature, the lower the relative humidity. To achieve high temperature and high humidity, it is only necessary to spray water vapor or atomized water droplets into the air of the cabinet to humidify. Low temperature and low humidity are relatively difficult to control, because the moisture content at this time is very low, and sometimes it is much lower than the moisture content in the atmosphere, and it is necessary to dehumidify the air flowing in the tank to make the air dry.
The common rapid temperature change test chamber generally refers to a constant rapid temperature change test chamber, which is controlled by setting a target temperature and the test chamber has the ability to automatically thermostat to the target temperature point. The control method of the constant temperature and humidity test chamber is similar. Set a target temperature and humidity point. The test chamber has the ability to automatically adjust the temperature to the target temperature and humidity point. The high and low temperature alternating test chamber has the program of setting one or more high and low temperature changes and circulations. The test chamber has the ability to complete the test process according to the preset curve, and can control the temperature rise within the range of heating and cooling rate capability. The rate of temperature drop, that is, the temperature rise and temperature drop rate can be controlled according to the slope of the set curve.
Similarly, the high and low temperature alternating heat and humidity test chamber also has a preset temperature and humidity curve, and the ability to control according to presets. Of course, the alternating test chambers all have the function of a constant test chamber, but the manufacturing cost of the alternating test chamber is higher, because the alternating test chamber needs to be equipped with a curve automatic recording device, a program control device, and the test chamber must be solved in the working chamber. When the temperature is high, the refrigerator is turned on. Therefore, the price of the alternating test chamber is generally 20% higher than the price of the constant test chamber. Therefore, we should be realistic and take the test method as the starting point, choose a constant test box or an alternating test chamber.
Different rapid temperature change test chamber manufacturers have different quality, so users need to understand the rapid temperature change test chamber and make more detailed choices.
Recomendações relacionadas
-
Basic Structure of Industrial Water Chiller
2012Basic structure of industrial water chiller: Industrial water chiller consists of compressor, condenser, evaporator, expansion valve and other accessories. 1. Compressor: in the industrial water chiller system, the compressor is the power to e...
Ver detalhes -
Operation method of reaction kettle for circulating heating device
2049The laboratory single-layer glass reactor equipped with the circulating heating device can place a flask containing the reaction solvent on the inner layer for stirring reaction, and the interlayer can realize constant temperature heating and cons...
Ver detalhes -
Importância dos fluidos frigorigéneos nos sistemas de ensaio de baterias de veículos de energia nova
2397Se o caudal do refrigerante no sistema de teste da bateria do veículo de energia nova for extremamente pequeno, o refrigerante começará a expandir-se a partir do primeiro espaço expansível na extremidade traseira da válvula de estrangulamento. A maior parte da expansão da extremidade traseira da...
Ver detalhes -
What Should Be Noticed In Detail When Installing A Precision Chiller?
2302First, when installation, everyone needs to check whether your cold water machine works normal, whether the accessories are all right, whether there is damage, so as to avoid problems in installation. Second, when installing, the site of the preci...
Ver detalhes
工業冷水機製造商 LNEYA Taiwan











