The safety of heat transfer oil in water-cooled chillers
In order to achieve better operating efficiency, water-cooled chillers need to choose branded heat transfer oil, but you need to pay attention to safe placement, a little carelessness will cause adverse effects.
Although the heat transfer oil of the water-cooled chiller has a higher boiling point, it is still a flammable liquid. Therefore, you should pay attention to safety when using it. Improper use may cause fire. The cause of the fire is caused by leakage. There are four main types of leakage and fire:
A. Fire in the heat preservation area.
Common misfire types in organic heat transfer oil systems. The heat transfer oil leaks at the instrument connection and penetrates into the heat preservation area. Then, in the presence of air, the circulating liquid and pipe heat will heat the heat conduction oil and gradually oxidize the liquid, causing the heat preservation area to be ignited and cause a fire.
B. Fire caused by pipeline leakage or burst.
The leakage or burst of the pipeline caused the heat transfer oil to flow into the hot gas flame zone and cause a fire.
C. The flash point causes a fire.
The factors that cause the flash point fire are higher than the low flash point temperature of the heat transfer oil, and there are heat transfer oil, air and fire sources at the same time.
D. Fire caused by process raw materials:
The main reason is that the heat-conducting oil leaks into the heating system, and its process raw materials are easily oxidized and have oxidizing substances, which causes a fire.
In addition to the above four types of fires, more attention should be paid to the use of gas-phase systems. If a large amount of heat transfer oil vapor leaks, aerosol mist may be formed. This mist may cause explosion and combustion in the air when exposed to an open flame.
Therefore, the heat transfer oil of water-cooled chillers is related to its operating efficiency and safety, so it is necessary to do a good job in the repair and maintenance of the hot oil system to prevent the leakage of the heat transfer oil.
Recomendações relacionadas
-
Considerações sobre a seleção de lubrificantes refrigerados a baixa temperatura
2406Quando se utiliza um refrigerador criogénico, é importante conhecer todos os aspectos do mesmo. Mas uma das coisas que precisa da atenção de todos é a escolha do tipo de lubrificante para o refrigerador, porque há muitos factores que influenciam...
Ver detalhes -
A introdução dos refrigeradores de recirculação de temperatura ultra baixa
1989Os desempenhos dos chillers de recirculação de temperatura ultra baixa são diferentes devido aos seus diferentes compressores. Em comparação com o compressor de pistão, a estrutura do compressor de parafuso tende a ser mais precisa, por isso, quando os utilizadores precisam de selecionar...
Ver detalhes -
How to use multiple reactors for high and low temperature integrated machine
2606Multiple reactors high and low temperature integrated machine temperature control system will be connected with thermal conductive synthetic oil and power supply before use, and multiple reactor high and low temperature integrated machine temperat...
Ver detalhes -
Types of Environmental Tests
2135The environmental chamber is one of the many types of experiments used in scientific research, product development, production and evaluation. The fundamental difference between environmental tests and other tests is that there are specific requir...
Ver detalhes
工業冷水機製造商 LNEYA Taiwan