Common Faults of Salt Spray Environmental Chambers
The enterprise users are often at a loss when dealing with common faults in the salt spray environmental chamber. For this reason, Wuxi LNEYA, a manufacturer of the salt spray environmental chamber, specially reorganized the related common fault treatment technologies of the salt spray environmental chamber.
Salt spray environmental chamber for sale
The salt spray environmental chamber cannot be heated
1. Heat the solid state relay, if there is no output, replace the solid state relay.
2. If the external dial has no output, replace the external dial.
3. If there is heating tube damage, check the heating tube resistance, replace the resistance if there is something abnormal.
4. Lack of water can cause heating shielding, check whether the water level is normal or not and whether the floating ball malfunctions or not.
5. If there is a malfunction of the over-temperature maintenance system, adjust the maintenance temperature value. If the fault still cannot be solved, replace the over-temperature maintenance system.
The heating temperature is abnormal
1. If the set temperature of the temperature controller of the environmental chambers for sale is too low, set the temperature controller at the required temperature.
2. If the set temperature of the safety maintenance switch of the environmental chamber is too low, set the safety maintenance switch at the required temperature.
3. If the set temperature of the temperature controller of the full bucket is too low, set the temperature controller at the required temperature.
4. If the set temperature of the safety maintenance switch of the full bucket is too low, set the safety maintenance switch at the required temperature.
The external dial doesn’t display
1. Check whether or not there is a power supply in the salt spray environmental chamber. If not, ask a professional electrician for a check.
2. Check whether or not the power switch is damaged. If damaged, replace the power switch.
3. Check whether or not the power circuit breaker is damaged. If damaged, replace the circuit breaker.
4. Check whether or not the external dial terminal has a power supply. If there is a power supply, it indicates that the external dial is damage, replace the external dial.
5. Check whether or not the power supply wiring terminal of the salt spray environmental chamber is blackened. If it is blackened, it indicates the possibility of burning out, replace the external dial.
If the failures the enterprise users are encountered are more serious than above, it is suggested to contact the salt mist environmental chamber manufacturer to solve the failure.
Recomendações relacionadas
-
Instruções de fuga interna do frigorífico de temperatura ultra baixa à prova de explosão
21691. Sound leak detection method: First, the refrigeration pipeline of the explosion-proof ultra-low temperature refrigerator is filled with nitrogen. Then use a stethoscope to check the interior. When you hear a leak in a certain area, mark it. Car...
Ver detalhes -
Qual é o refrigerante do equipamento de arrefecimento por circulação de água?
1924Diferentes indústrias exigem diferentes temperaturas de refrigeração para o equipamento de arrefecimento de água em circulação, pelo que os refrigerantes selecionados também são diferentes. Ao escolher o equipamento de arrefecimento por circulação de água, também é necessário ter um conhecimento claro das...
Ver detalhes -
Manutenção do circulador de alta e baixa temperatura na indústria farmacêutica
1870O circulador de alta e baixa temperatura na indústria farmacêutica é também um equipamento de controlo de temperatura cada vez mais comum em todos os sectores da vida. É inevitável que o equipamento tenha de ser mantido após uma utilização prolongada. Como fazer a manutenção...
Ver detalhes -
Pontos de atenção para a inspeção diária do equipamento de controlo de baixa temperatura a menos 30℃
1901O equipamento de controlo de baixas temperaturas a menos 30 graus Celsius é uma unidade de refrigeração ou também chamada unidade de refrigeração. A diferença em relação ao refrigerador é a gama de temperaturas. É um equipamento de baixa temperatura comummente utilizado na indústria...
Ver detalhes
工業冷水機製造商 LNEYA Taiwan