Como resolver a falta de capacidade de arrefecimento do sistema de ciclo de arrefecimento de semicondutores?
The semiconductor cooling cycle system is a device for cooling the heating part of the semiconductor in the refrigeration equipment. It is commonly used to test semiconductor IC parts, automotive electronic parts, optical fiber components, telecommunication sensor parts and components. Once the cooling capacity is insufficient during operation, it needs to be checked in time to see if there is a fault.
When the cooling capacity of the semiconductor cooling cycle system is insufficient, first determine whether it is because of the filter clogging. The clogging of the filter includes: suction filter clogging and drying filter clogging. At this time, it only needs to be cleaned and it can operate normally.
By observing to determine whether the expansion valve is too small or too large, adjust the amount of water. The leakage of the filling agent in the temperature sensing bulb of the expansion valve can be solved by opening the cooling tower. Dirty or ice blockage of the throttle valve can be solved by cleaning.
After the compressor bearing of the semiconductor cooling cycle system is worn, the clearance is too large, and the problem of insufficient cooling capacity can be solved through maintenance and replacement. Choose parts with precise structure, high reliability and long life. To ensure the stable operation of the unit. The condenser is a shell and tube condenser, which can optimize the temperature field distribution and refrigerant flow field distribution, and has high heat exchange efficiency. The outer fin design of the heat exchange tube enhances heat exchange and condensation, and improves the heat exchange efficiency outside the tube.
Insufficient refrigerant charge of the semiconductor cooling cycle system, excessive refrigerant leakage, etc. may also cause insufficient cooling capacity of the semiconductor cooling cycle system. These problems can be solved by adding or subtracting the refrigerant charge, checking for leaks, and adding refrigerant after maintenance. solve. If the evaporator is too small, the evaporator has too thick frosting.>There are a lot of lubricating oil in the evaporator. The condenser or the outlet valve of the liquid reservoir is opened too small, insufficient cooling water or too high water temperature, etc., will also cause the cooling of the semiconductor cooling cycle system Not enough. If the evaporator is too small, you can reduce the heat load or replace the evaporator. If the evaporator is too thick, you need to dissolve the frost regularly. There is a large amount of lubricating oil in the evaporator. If the outlet valve is opened too small, open the outlet valve appropriately.
In addition, there is excess air in the refrigeration system of the semiconductor cooling cycle system, and the energy adjustment instructions are not correct, and attention should be paid. Excess air in the refrigeration system can be solved by exhaust air. If the energy adjustment indicator is incorrect, it may be that the indicator light is broken, which can be solved by maintenance and replacement. The reasons for insufficient cooling capacity are as shown above, and users are advised to contact the semiconductor cooling cycle system manufacturer in time for after-sales solutions.
Recomendações relacionadas
-
Boas notícias! Wuxi Guanya LNEYA Refrigeração ganha um novo nome
4363De acordo com o `` Aviso sobre a publicação dos resultados da avaliação das empresas Unicorn e Gazelle na Zona Nacional de Demonstração de Inovação Independente do Sul de Jiangsu 2019 '' emitido pela Jiangsu Sunan National Independent Innovation Demonstratio...
Ver detalhes -
Diretrizes para a utilização e manutenção seguras do congelador de temperatura ultra baixa
19061. É necessário compreender a influência do ambiente nos frigoríficos.2. Familiarizar-se com os conhecimentos básicos de funcionamento, manutenção e conservação3. Desenvolver bons hábitosDeixar o frigorífico respirar livremente;Deixar que o ar à volta do frigorífico ci...
Ver detalhes -
Onde é que os circuladores de aquecimento industrial podem ser úteis?
2231O circulador de aquecimento industrial pode fornecer um dispositivo de circulação de fonte fria e fonte de calor, e tem uma ampla gama de trabalho. É utilizado nas indústrias farmacêutica, química, biológica e outras para fornecer fontes de calor e frio para reac...
Ver detalhes -
Precauções para a colocação de um refrigerador industrial arrefecido a ar
2748A qualidade e a utilização dos chillers industriais refrigerados a ar são muito importantes. Ao mesmo tempo, a operação do utilizador não pode ignorar a colocação da posição. Apenas a colocação correta da posição e o equipamento de alta qualidade podem alcançar uma operação de alta eficiência...
Ver detalhes
工業冷水機製造商 LNEYA Taiwan