Changes in temperature control methods during semiconductor testing
As the use of semiconductor devices expands into new areas, such as automotive electronics, stricter requirements are imposed on their performance. Example: Devices are now required to operate at very low temperatures (about -40°C). To determine whether a particular semiconductor device will operate at these temperatures, the device needs to be fabricated. Testing must be performed at low temperatures before it can be delivered to customers. Conventional methods for testing semiconductor devices at low temperatures include placing a plurality of such devices in a conventional temperature chamber and reducing the ambient temperature therein to the required test temperature. The limitation of this method is that it usually takes about half an hour to reduce the temperature in the chamber to the test temperature. Due to the limited number of devices that can be installed in a given chamber, a half-hour cycle occurs every time a new batch of devices is tested. For production line technology, such long wait times are quite inefficient.
Low temperature test method, which not only reduces the time required to reach the test temperature, but is also compatible with current production line technology. In order to control the temperature of the chuck and thus the temperature of the wafer under test, tool designers have used a variety of techniques. In theory, pure water is very suitable for temperature control of chucks. Its limitations are obvious: Under normal atmospheric pressure, water cannot be used at temperatures below freezing or above boiling point. For actual wafer test operations, the range of 0°C to 100°C is too narrow.
By using a mixture of water and glycol similar to the antifreeze used in automotive radiators, a partial solution to the problem of narrow temperature ranges can be found. This mixture can significantly extend the operating temperature range. Thermal systems using water or water / glycol mixtures as coolants are rarely used in semiconductor testing. They can be used over a wide temperature range, typically around -70°C to + 120°C. Compared to water, even compared to purified water, the cost of synthetic coolants is high. Since these liquids evaporate over time even in closed circuits, the system needs to be refilled periodically.
Aiming at the problems in the semiconductor test industry, LNEYA independently developed and generated a semiconductor test cooling and heating system, which is mainly used for temperature test simulation in semiconductor testing. It has a wide temperature orientation and high temperature rise and fall. The temperature range is -92°C ~ 250°C, suitable for various test requirements. LNEYA is committed to solving the problem of temperature control hysteresis in electronic components. Ultra-high temperature cooling technology can directly cool from 300°C.
The working principle of the cooling and heating system is through the heating and cooling process of the heat-conducting liquid / refrigerant inside the device, taking away the heat on the test bench through the input / output / heating the required heating device to meet the test temperature requirements.
This series of cooling and heating system equipment is suitable for precise temperature control of electronic components. Especially used in the manufacture of semiconductor electronic components in harsh environments, the assembly of IC packages and the engineering and production test stages include electronic thermal testing and other environmental test simulations at temperatures (-45°C to + 250°C). Once put into practical use, these semiconductor devices and electronics can be exposed to extreme environmental conditions to meet stringent military and telecommunications reliability standards.
Recomendações relacionadas
-
Como manter um desempenho estável do arrefecedor de óleo de laboratório biofarmacêutico?
17711. Um ambiente de trabalho adequado para evitar várias falhas do refrigerador de óleo no laboratório biofarmacêutico precisa de proporcionar um melhor ambiente operacional para o equipamento. Manter o ambiente limpo e arrumado, reduzir o impacto de vários factores...
Ver detalhes -
Falhas comuns das câmaras ambientais de pulverização de sal
2036Quando se depara com algumas falhas comuns das câmaras ambientais de pulverização de sal, como resolvê-las? A Wuxi Guanya Refrigeration Technology Co., Ltd. trouxe as dicas de falha relevantes da seguinte forma: A câmara ambiental de pulverização de sal não pode pulverizar...
Ver detalhes -
Descrição do sistema de alimentação eléctrica e dos instrumentos de controlo eletrónico do congelador de temperatura ultra baixa
2273O congelador de temperatura ultrabaixa precisa de ser testado após um longo período de utilização. A que se deve prestar atenção quando se inspecciona a fonte de alimentação e o sistema de instrumentos de controlo eletrónico? Verificar a fonte de alimentação do congelador de temperatura ultrabaixa e o ...
Ver detalhes -
Temperatura de recristalização e factores que a influenciam?
1710A recristalização é o processo de recristalização de cristais a partir de uma solução ou fusão depois de serem dissolvidos num solvente ou fundidos. A recristalização pode purificar substâncias impuras ou separar sais misturados uns dos outros. Entre eles, é a r...
Ver detalhes