Vários métodos comuns de resolução de problemas para congeladores de temperatura ultra baixa em laboratórios
Although the refrigeration system and control circuit of ultra low temperature freezer in laboratory are complex, the common faults are mainly circulating system and circuit part.
Following are several common faults of ultra-low temperature refrigerators and their troubleshooting methods:
1. After power supply is switched on, the air switch of the main power supply is automatically disconnected.
Elimination method: Check whether the compressor of refrigeration system is damaged or not, and replace the parts if damaged. After replacing the fittings, turn on the machine to check whether it is normal. The fault is usually caused by unstable power supply, because the * stage starts first, so the damage is usually in stage. In this case, as long as the delay regulated power supply is installed, the fault will not occur again.
2. Stop working before the temperature in the box reaches the set temperature.
Exclusion: Although the temperature in the box has not reached the set temperature, the panel display temperature has reached the set temperature. This is due to the damage of the thermistor which detects the temperature and the need to replace the parts. If there is no original accessories, a set of temperature control system can be re-installed to eliminate the failure.
3. Poor refrigeration effect may be refrigerant leakage
4. If the ultra-low temperature refrigerator does not start in winter, it may be that the thermostat regulation value is too small.
Somos uma fabricante de congeladores de temperatura ultra baixa. Bem-vindo a escolher os nossos produtos.
Recomendações relacionadas
-
Quais são os sistemas de teste de potência para baterias de automóveis de energia nova?
1951The LNEYA power battery system is tested for battery testing of new energy vehicles, but modern new energy vehicles have many types of batteries. So what are the characteristics? The ternary lithium battery refers to a lithium battery in which the...
Ver detalhes -
Analysis of operating parameters and working conditions of automobile power module cooling system
2264Before choosing, you need to know what factors are related to the operating parameters and working conditions of the automotive power module cooling system. Then, from which aspects? 1. Evaporating pressure and evaporating temperature In the ope...
Ver detalhes -
Solução para a incapacidade de arrefecer o refrigerador industrial de recirculação de alta e baixa temperatura
2206When the high and low temperature recirculation chiller system is in use, what is the general cause if the high temperature cannot be reduced? How should we deal with such failures? First, let’s analyze the principle and method of cooling. The c...
Ver detalhes -
Characteristic Analysis of Air Cooled Industrial Chiller
1736Industrial air-cooled chillers are generally integral machines, that is, evaporator, compressor and condenser are made together. For a slightly high-power air-cooled industrial chiller, the heat dissipation of the condenser cooling fan needs to be...
Ver detalhes
工業冷水機製造商 LNEYA Taiwan