Existem normalmente três formas de controlar a temperatura dos reactores de laboratório
1. Manual control: Manually operate the knob on the front of the reactor controller.
2. Control by PC: The PC and the controller are connected by a network cable, and the operation is carried out on the PC.
3. Controlled by thermostat: Silicone oil is heated through the thermostat, and the thermostat naturally has a temperature control function. Although the thermostat heating limit (usually 250°C) is not as high as that of electric heating (can be as high as 400-500°C), the thermostat rises and falls smoothly, and the low temperature can reach -60/-80°C.
Our LNEYA laboratory reactor temperature control system belongs to the third category. However, the temperature control range is from -120 degrees to 350 degrees. It adopts a fully enclosed pipeline design and a high-efficiency plate heat exchanger, which reduces the demand for heat transfer oil, improves the heat utilization rate of the system, and realizes rapid temperature rise and fall. Continuous temperature control can be achieved in the temperature range of minus 90 degrees to 195 degrees and minus 70 degrees to 220 degrees without pressure.
Jacketed glass reactors are popular in current chemical experiments. The supporting temperature control equipment has also become a matter of widespread concern in the industry. It is known that the cooling and heating temperature in the reaction process has an absolute influence on the reaction process and results. The analysis of the temperature control equipment’s ability to increase and decrease the temperature of the material has become the basic basis for choosing chiller. Then the cooling and heating capacity is not only estimated by imagination and experience, but requires scientific analysis and calculation methods, and needs to calculate the required heating power and cooling power according to the heating rate and cooling rate.
When our technicians communicate with customers, they will first understand the requirements of engineering parameters, such as high and low temperature, how long is the temperature control time, etc., so as to calculate the cooling power and heating power of the chiller required, and determine the available chiller. model, to give customers the most complete temperature control solution. If you also have this need, you can contact us.
Recomendações relacionadas
-
Precautions for the use of cooling and heating circulation device for lithium battery testing
1930As a professional experimental test auxiliary instrument, the cooling and heating circulation device for lithium battery testing is the circulating supply end of the cold source and the heat source, with a wide operating range. It is used in pharm...
Ver detalhes -
Manutenção de rotina do equipamento de controlo da temperatura do multi-reator tcu
1847O equipamento de controlo da temperatura do multi-reator TCU é amplamente utilizado em departamentos de investigação como petróleo, química, instrumentos electrónicos, física, química, bioengenharia, testes de propriedades físicas e análise química, faculdades e universidades...
Ver detalhes -
Como controlar a temperatura de emulsificação do emulsionante?
1964Um bom produto de creme não se reflecte apenas na qualidade das matérias-primas, mas também tem uma grande influência no processo de emulsificação durante a produção, como a textura e a estabilidade do produto, e o controlo da temperatura durante a produção...
Ver detalhes -
Wuxi Guanya: Foco na I&D de equipamento de aquecimento de refrigeração para ajudar a desenvolver novas energias
2472Em 17 de outubro de 2018, a API de três dias foi realizada no Nanjing International Expo Center. A exposição estava lotada de pessoas. Wuxi Guanya era um visitante frequente da API. Wuxi Guanya Tecnologia de Refrigeração de Temperatura Constante Co., Ltd. (aqui ...
Ver detalhes