The softening of water is also an important problem in the process of using chillers.The pH value of water also needs to be continuously observed. The optimum pH value should be equal to 7. The pH value greater than 7 will cause terrible corrosion. If no measures are taken, fouling will be built in the evaporator and die, which will play an insulating role, and the energy conversion effect will be reduced by 30% in severe cases. Obviously this requires consideration of the softening of hard water.
The most effective method is to configure an electronic hard water softener in the system, which is designed and manufactured separately from the exchange principle. Softeners of different specifications can be configured according to different flow rates, which can be directly connected to the circulating water pipeline.
Generally, the cost of water treatment softener is not too high, and a certain proportion of scale removal agent can be added to the periodic circulation system. Generally, when the injection moulds are cooled and the pressure of ice water is 0.1-0.2 mpa, the requirements can be met. When the pressure requirement is higher than 0.2 mpa, it is necessary to plan separately in order to use the corresponding pressure from the pump to meet the need of water supply.
Somos uma top chiller manufacturer. Bem-vindo a comprar os nossos produtos.
Recomendações relacionadas
-
What are the factors related to the selection of heating and refrigeration circulators?
1989Heating and refrigeration circulators are used in many laboratory projects. They are usually equipped with reactors and reactors for cooling, heating and temperature control. Then, what factors are related to the selection of heating and cooling i...
Ver detalhes -
Solução para o derrame de óleo do circulador de arrefecimento e aquecimento do reator
1814When we use some reactor cooling and heating circulators, we will find that the system pressure fluctuates up and down as the temperature rises, and the oil tank is overflowing. So what are the reasons for these conditions in the cooling and heat...
Ver detalhes -
Porque é que o modo do circulador de água de arrefecimento é principalmente a circulação de água?
1719O circulador de água de arrefecimento é uma forma de utilizar a água para arrefecimento. Com o aumento da temperatura ambiente, muitas empresas também descobriram que a utilização de água em circulação está a aumentar. O suplemento de água em circulação tem como objetivo o arrefecimento da água...
Ver detalhes -
Medidas para o funcionamento estável do destilador molecular de curto alcance
1878Se o destilador molecular de curto alcance for ineficiente durante o funcionamento, isso afectará a utilização do sistema de controlo da temperatura de aquecimento por refrigeração associado. Como é que o destilador molecular de curto alcance mantém um funcionamento estável? Se o vapor...
Ver detalhes
工業冷水機製造商 LNEYA Taiwan