O que devo fazer se houver ruído de refrigeradores industriais de refrigeração e aquecimento?
The industrial cooling and heating temperature control equipment adopts a PID algorithm temperature control system to accurately adjust the temperature based on the detected temperature and the set temperature value, improving the drawbacks of traditional manual control of the reaction kettle.
1. The industrial cooling and heating temperature control equipment, the chiller circulating pump, converts electrical energy into mechanical energy to promote the liquid phase circulation of the heat transfer oil, and transfers heat to the reaction kettle. The heat transfer oil exchanges with the materials in the reaction kettle and then returns to the oil heater, where it is heated again under the pressure of the pump and enters the next cycle. Through repeated cycles, heat is transferred and transported, heated and cooled, or the temperature of the reactor is maintained to meet the temperature requirements required by the production process.
2. When high noise occurs during the operation of the industrial cooling and heating temperature control equipment, the chiller needs to be inspected and promptly addressed if any problems are found. The internal components of the industrial grade cold and hot temperature control thermostat are excessively worn, such as the wear and tear of the cylinder body and valve plate of the plunger pump, as well as the wear and tear of the matching parts between the plunger and the plug hole, causing serious internal leakage in the pump. When the pump outputs high-pressure and low flow oil, flow pulsation will occur, causing high noise.
3. The pump valve plate is also one of the important components that can easily cause noise. Industrial cooling, heating, and temperature control equipment. During use, the water chiller may shorten the unloading groove and change the unloading position due to surface wear or oil sludge deposition at the opening of the unloading groove, resulting in oil trapping and higher noise.
4. When air is mixed into the cold water oil of industrial cooling and heating temperature control equipment, it is easy to form cavitation phenomenon in its high-pressure zone, which spreads in the form of pressure waves, causing oil oscillation and causing cavitation noise in the system.
Recomendações relacionadas
-
Quais são os componentes do sistema de vários dispositivos de destilação?
15011. Um conjunto completo de equipamento de destilação de trajeto curto: incluindo evaporador de trajeto curto, sistema de aquecimento, sistema de alimentação, sistema de arrefecimento, sistema de vácuo, unidade de recolha de material, etc.; 2. Um conjunto completo de equipamento de destilação de película fina: incluindo ...
Ver detalhes -
What is the temperature control of the reactor?
2272The reactor cooling system is one of the common equipment in the chemical industry. It can not only heat but also refrigerate to meet the needs of heating and cooling in the reaction process. There are usually three ways to control the temperatu...
Ver detalhes -
Método de controlo da paragem do refrigerador arrefecido a água de uma única caldeira de reação
2336The reaction kettle water cooled chiller has a wide range of accessories and equipment. In actual use, it needs to be provided with regular rest time. In order to maintain the stable performance of the refrigerator during long-term operation, it i...
Ver detalhes -
O que deve ser considerado ao comprar um sistema de arrefecimento de potência de motor arrefecido a óleo?
2014A compra de objectos não é mais do que baseada em vários tipos de métodos: informar-se junto das pessoas que o rodeiam, pesquisar e consultar a Internet por si próprio, de modo a evitar alguns desvios. 1. Requisitos dos parâmetros: Encomendar na Internet é...
Ver detalhes
工業冷水機製造商 LNEYA Taiwan