Преимущества низкотемпературного охлаждающего рециркуляционного чиллера
Low temperature cooling recirculating chiller is a kind of refrigeration using compressor, and the circulating pump provides cold source to maintain the temperature range from – 2 5℃ to 30 ℃. The refrigeration recirculating chiller has a space-saving vertical configuration and good heat dissipation effect. It can effectively control the external closed liquid loop when the temperature is far lower than 0 ℃. It is suitable for water, oil or other media of the manufacturer. All recirculating chillers can be connected with other equipment through hoses and used as a constant temperature source.
The high and low pressure of the low-temperature recirculating chillers are 2.5bar and 0.7bar respectively. The air-cooled fully enclosed compressor unit is used for refrigeration, microcomputer intelligent control, automatic opening and delayed closing of the refrigeration system, overheating and current multiple protection devices. It is widely used in petroleum, chemical industry, medicine, life science, metrology, light industry, scientific research and other fields.
Преимущества низкотемпературного охлаждающего рециркуляционного чиллера
1. One of the characteristics of the refrigeration cycle is the large single pressure ratio, but with the increase of the pressure ratio, the efficiency of the screw chiller decreases and the power consumption is large.
2. In order to expand the application range of screw chiller, improve the performance at low temperature and achieve the purpose of energy saving.
3. Taking advantage of the unidirectional operation of suction, compression and exhaust of the screw machine, an intermediate air supplement orifice can be set at a certain position where the rotor starts to compress, so that the single screw refrigerator can operate according to two compression, that is, the screw chiller with economizer.
4. It is usually used when the evaporation temperature is – 25 ℃ ~ 30 ℃. Compared with the original single screw chiller, the refrigeration capacity and refrigeration efficiency are greatly improved, and electric energy can be saved at the same time.
Похожие рекомендации
-
How To Reduce Operating Costs For Electric Vehicle Power Battery Testing Equipment?
1997Since many harsh environments easily affect the operating power of electric vehicle power battery testing equipment, in order to ensure the safety of equipment operation, enterprises need to choose a suitable safety environment when installing ele...
Посмотреть детали -
What should you pay attention to when using the cooling and heating oil bath?
1771In the high and low temperature control, cooling and heating oil bath is one of the more important equipment. What aspects do users need to pay attention to when running the device? The cooling and heating oil bath equipment should be kept clean a...
Посмотреть детали -
Как выбрать стеклянный реактор? Как подобрать систему контроля температуры?
1929Стеклянные реакторы-чайники необходимы для многих лабораторных установок и обычно используются с системами контроля температуры. В химической и фармацевтической промышленности импортный стеклянный реактор - это, по сути, необходимость, а холодильный нагреватель...
Посмотреть детали -
Как установить -60°C криогенный охладитель производители оборудования
2357Криогенные холодильники -60℃ используются в холодильной и химической промышленности, поэтому на какие вопросы следует обратить внимание при установке? Профессиональные производители LNEYA говорят вам, что вы должны установить в соответствии с инструкцией...
Посмотреть детали