New energy automobile motor comprehensive test system
When the LNEYA new energy vehicle motor integrated test system is running, the control panel settings are required. At the time of setting, if the user does not know how to use it, you can check the manual for use.
The indicator of the new energy vehicle motor comprehensive test system controller lights up after power-on. In the previous second, the upper row of digital tubes displays “dF01” (01 is the version number), and the lower row of digital tubes displays the sensor input type “In-P”. After two seconds, the upper row of digital tubes display the upper range value, and the lower row of digital tubes display the lower range value. Then click the “Settings” button to enter the temperature setting state. The upper row of digital tubes displays “SP2”, and the lower row of digital tubes displays the temperature setting value. After entering the temperature setting state, modify the required by increasing or decreasing the keys. The temperature setting value, and then click the “Settings” button, the controller automatically saves the temperature setting parameters and exits the temperature setting state. If there is no key pressed within 60 seconds in the temperature setting state, the controller will automatically return to the normal display state, and the parameters will not be saved. In the non-setting state, click the “Reduce/View” button, the upper row of digital tubes will display “TS1”, the lower row of digital tubes will display the road temperature setting value; then click the “Reduce/View” button to display the upper row of digital tubes. TP1”, the lower row of digital tubes display temperature measurements. Wait for 5 seconds or click the “Reduce/View” button to exit the road temperature viewing status.
In the non-set state of the new energy vehicle motor test system (invalid in the temperature setting and internal parameter setting state), you can control the circulation pump to be turned on or off by clicking the “Cycle Allow” button. When the value of cPS (see internal parameter table 3) is 1, the cooling permission must be turned on and the heating enable button is activated. When the value of cPS is 0, the cooling permission and heating permission button can be turned on separately. In the non-set state of the new energy vehicle motor test system (invalid in the temperature setting state and internal parameter setting state), click the heating enable button, the “heating permission” indicator lights up, the controller allows the heating output; click on the heating The enable button, the “heat enable” indicator is off, and the controller disables the heating output. In the non-setting state of the new energy vehicle motor test system (invalid in the temperature setting state and internal parameter setting state), click the cooling permission button, the “cooling permission” indicator lights up, when the temperature meets the cooling demand, the cooling control Output. Then click the Cooling Allow button and the “Refrigeration Allowed” indicator goes out. The controller disables the cooling output.
The control panel of the new energy vehicle motor comprehensive test system is recommended not to modify the settings by itself to avoid bad faults and prevent operation.
Похожие рекомендации
-
Инструкция по применению системы вторичной циркуляции теплоносителя
1949The thermal oil secondary circulation system is equipped with various instruments and equipment for temperature control. When using it, you need to pay attention to its safety knowledge and safer operation. LNEYA heat transfer oil secondary circul...
Посмотреть детали -
Introduction to mixed solution of glycol chilling systems (glycol chillers)
1888Glycol chillers are industrial refrigeration systems that use a type of antifreeze called glycol, mixed with water, to lower the freezing point in the application of the chilling system. Glycol is a class of organic compounds that belong to the ...
Посмотреть детали -
Аксессуары для систем контроля температуры полупроводниковых холодильников
2124В испарителе, поскольку жидкость испаряется в испарителе полупроводниковой холодильной системы температурного контроля, процесс из жидкости в газ, из-за изменения нагрузки, часть хладагента может быть не полностью испарена...
Посмотреть детали -
What should I pay attention to when adding refrigerant to a water-cooled chiller
2157In our life, we believe that everyone is very familiar with refrigeration. In the central air conditioning and industrial production process cooling industry, small water-cooled chillers is more common. This unit is composed of a compressor in the...
Посмотреть детали
工業冷水機製造商 LNEYA Taiwan











