Метод управления отключением водоохлаждаемого холодильника одиночного реакционного котла
The reaction kettle water cooled chiller has a wide range of accessories and equipment. In actual use, it needs to be provided with regular rest time. In order to maintain the stable performance of the refrigerator during long-term operation, it is necessary for the user to master the method of stopping the operation according to the actual use requirements, and to reduce the excessive wear of the equipment.
1. When it is necessary to shut down, first consider ensuring that the reactor freezer is within the shutdown range before performing all shutdown operations. In order to avoid the generation of high pressure, the user needs to close the suction stop valve to stop the operation of the compressor.
2. After completing the shutdown of the refrigerator compressor, it is necessary to operate the oil pump. Return the slide valve of the freezer to the 0-scale position so that the load reduction reaches zero. At this time, the oil pump will immediately stop all operations.
3. For the reaction kettle water cooled chiller, the operation of the water pump and cooling water tower needs to be stopped in the latter step. After stopping this type of equipment, the entire power supply can be turned off and the entire shutdown process can be completed. Ensure that the reactor water cooled chiller is in the shutdown state.
Precautions for reactor shutdown:
1. If the machine stops for a long time, special treatment is required. Including the condenser and the evaporator, the refrigerant needs to be completely pumped to the condenser, and at the same time all the water sources are discharged to avoid problems such as corrosion.
2. After the shutdown is completed, various accessories need to be carefully tested. The shutdown process is more particular, and the correct shutdown steps can prolong the service life of the equipment.
For the reactor freezer that has been shut down for a long period of time, careful testing is required to ensure that the equipment is kept away from various corrosive substances.
Похожие рекомендации
-
Three Common Failures Of Air Cooled Screw Chiller
26641. Communication Failure: Computer controller controls various modules by telecommunication lines and total interface board, so the main cause of communication failure is poor contact or break of communication lines, especially the interface oxida...
Посмотреть детали -
Подробное описание технологии одностоечного охлаждения
2365С непрерывным развитием времени постоянно развиваются и технологии сверхнизкотемпературного охлаждения. В списке ультранизкотемпературных морозильников, Wuxi Guanya продолжает продвигаться на рынке холодильного оборудования с ...
Посмотреть детали -
Что делать, если теплообменного масляного нагревателя недостаточно?
2122Устройство электрического нагрева теплоносителя также называется высоко- и низкотемпературной интегрированной машиной, холодильной и нагревательной интегрированной машиной, холодильно-нагревательной системой динамического контроля температуры, и заменяет традиционную электрическую...
Посмотреть детали -
Routine maintenance points of special refrigeration units for laboratory instruments
2255Industrial refrigeration units dedicated to laboratory instruments are used more in the pharmaceutical and chemical industries, and care must be taken when using them. The daily maintenance of the industrial refrigeration unit dedicated to experim...
Посмотреть детали