Comparison of Three Test Methods for Low Temperature Chamber
The method of guaranteeing the fluctuation of uniformity in high and low temperature test box is to adopt the wind circulation mode, in which the motor drives the fan to produce the wind circulation, thus forming the direction of wind speed. Non-forced air circulation test is a kind of test to simulate the influence of free air conditions, which is more suitable for the test of heat dissipation test samples. When forced air circulation is not used or test conditions are not guaranteed, forced air circulation can be used. One of the methods used in the test chamber is large enough to meet the test requirements without forced air circulation, but the required low temperature can not be maintained without forced air circulation in the chamber. Forced air circulation is required for refrigeration or heating of low temperature chamber.
2. Non-heat dissipation test samples and heat dissipation test samples
When the temperature of the test sample is stable during the conditional test period, the hottest spot temperature on the surface of the test sample is higher than the ambient atmospheric temperature by 5 degrees under the condition of free air, which is considered to be heat dissipation, whereas the non-heat dissipation test sample is considered to be heat dissipation. All the storage test and the test period without power or load, the test samples are non-heat dissipation test samples, the test using low temperature test method.
3. Non-heat dissipation test samples
Temperature gradient test of low temperature chamber(the former is a rapid temperature change test box and the latter is a cryogenic tester).
(1) Temperature gradient test: first, test samples with room temperature are put into the same room temperature test box. Then turn on the cold source to gradually cool the temperature in the box to the specified test temperature. If the test sample is too large or too heavy, or because of the complex functional test wiring, it can not be put into the cryogenic chamber without frosting in the catastrophe test, the test should also be used.
(2) Temperature catastrophe test: first adjust the temperature of the test chamber to the specified test temperature, and then put the test sample with room temperature. This test method is applicable when the known temperature abrupt change does not produce operation on the test sample.
Похожие рекомендации
-
Метод отключения в случае отказа высокоточного высокотемпературного циркулятора
2213Высокоточный высокотемпературный циркулятор является одним из видов оборудования, используемого в фармацевтической и химической промышленности для поддержки различных реакторов. Если во время эксплуатации произойдет аварийное отключение электроэнергии, пользователям следует обратить внимание на оперативн...
Посмотреть детали -
Semiconductor refrigeration temperature control table cooler operation instructions
2168The power supply switching of the control system of the transformer cooling system of the semiconductor refrigeration temperature control station uses the imported dual power automatic switching device. Its main function is automatic switching bet...
Посмотреть детали -
Explosion-proof hot and cold machine winter maintenance instructions
2438When the explosion-proof type hot and cold integrated machine is used at the end of the day or when it is not used by the standby, be sure to disconnect the cooling water connection pipe, clean the remaining cooling water in the pipe, and store it...
Посмотреть детали -
Какие требования предъявляются к оборудованию для контроля температуры охлаждения и нагрева 500-литровой емкости
1802The 500-liter reaction kettle cooling and heating temperature control equipment is a dynamic temperature control system, a fully closed circulation pipeline, which can be automatically heated or cooled according to the process requirements. 1. A s...
Посмотреть детали
工業冷水機製造商 LNEYA Taiwan