What should you pay attention to when using the cooling and heating oil bath?
In the high and low temperature control, cooling and heating oil bath is one of the more important equipment. What aspects do users need to pay attention to when running the device?
Сайт cooling and heating oil bath equipment should be kept clean and dry. It is strictly forbidden to heat the solution in the stainless steel pot without burning the heater to avoid burning the heater. If the measured temperature differs greatly from the actual temperature, it is usually obtained with the wrong sensor. Place the sensor in boiling water and the meter should display 100 °C. Otherwise check that the sensor is consistent with the meter input type.
Сайт cooling and heating oil bath meter indicates that the HHH is the measured value that is outside the meter range or the thermocouple is broken. It indicates that the LLL is the measured value lower than the lower limit of the meter range or the thermocouple is reversed. The instrument of the cooling and heating oil bath shows normal, the temperature suddenly loses control, and the external load should be checked for short circuit or open circuit.
When the cooling and heating oil bath is not working, the power should be cut off. To ensure safety, please connect the ground wire during use. The electric power and the heat taken away from the load by the refrigerant need to be removed from the radiator at the front hood. The front hood is filled with dust and cotton wool, which will prevent the heat from being dissipated and the cooling effect will be greatly reduced. Generally, the decrease in cooling capacity under normal use conditions is caused by poor ventilation or high ambient temperature.
When the cooling and heating oil bath is in operation, it is necessary to understand these points of use and then operate better.
Похожие рекомендации
-
Model and size selection of cooling and heating circulator (pilot plant temperature control system)
2046The cooling and heating circulator adopts mechanical refrigeration, the low-temperature heating tube heats the high temperature, and the canned pump is used as the circulating pump. The liquid circulation of the whole system is closed and consists...
Посмотреть детали -
Меры предосторожности при замене холодильного масла в системе охлаждения зарядного устройства автомобиля
1992Во время работы системы охлаждения бортового зарядного устройства необходимо обращать внимание на состояние холодильного масла. После запуска компрессора внимательно следите за изменением температуры и давления масла. Если температура масла меняется...
Посмотреть детали -
Routine maintenance points of special refrigeration units for laboratory instruments
2255Industrial refrigeration units dedicated to laboratory instruments are used more in the pharmaceutical and chemical industries, and care must be taken when using them. The daily maintenance of the industrial refrigeration unit dedicated to experim...
Посмотреть детали -
Как заменить четырехходовой клапан машины охлажденной воды?
2206После длительного использования четырехходовой клапан машины для охлажденной воды нуждается в своевременной замене, так как же его заменить? Вы можете ознакомиться с предложениями. При замене машины для охлажденной воды необходимо снять соединительную трубку...
Посмотреть детали
工業冷水機製造商 LNEYA Taiwan