Leakage Detection Tips of Low Temperature Freezer
Pressure leaking detection
It is an effective way to check and find out the leakage point. The leakage detecting pressure of refrigerating system of freezer is relevant to the type of refrigerating fluid and cooling and the location of tube. The leakage detecting pressure of high-pressure system is 1.25 times greater than designing condensing pressure, while that of the low-pressure system is near 1.2 times higher than saturation pressure in condition of the temperature in summer. With it, refrigerating plant can stop from leakage no matter it is working or parking. Some cooling system should be detected according to the provisions of the pressure if there is a predefined acceptance or leakage detection standard. Obviously, the leakage detecting pressure can not be raised casually, otherwise it is likely to destroy the equipment, resulting in an accident.
Bubble test
It is a widely used detecting method at present , especially for those medium and large freezer systems that take advantage of it to search for the leak point. Generally, bubble test is comprised of soap or soap powder. The solution of soapy water should not be too ropy; if not, the viscosity will be too big to flow, worsening the sensitiveness of the test. But as an editor of Whose Low Temperature Freezer Is Best,i would like to tell you that the modulation not ought to be too dilute, or else the fluidity will be too large to be adhere to the surface of the equipment, being hard to form the bubbles. The soapy water can be applied the leaky point with hairbrush directly to observe whether this position is blistering. When it comes to the positions that are difficult to observe straightway, mirror reflection and flashlight can be used. After the test, the soapy water should be dried up in case of corrosion.
LNEYA have more freezers for sale and low temperature freezer price is really affordable.
Похожие рекомендации
-
How to reduce the condensing pressure of the heating circulator unit?
2194During the operation of the heating circulator unit, the temperature change inside the equipment will cause the condensing pressure to change. Especially in summer when the condensing pressure is too high, the power consumption of the compressor w...
Посмотреть детали -
Factors affecting the cooling capacity of the chiller of the chemical reactor cooling system
2734There are various types of chillers, such as air-cooled chillers, water-cooled chillers, etc. But no matter what the chiller is, there are some factors that affect the cooling capacity of the chiller. A cooler is an energy-saving device that is co...
Посмотреть детали -
Соответствующее знание холодильного оборудования реакторов
1937The reactor refrigeration equipment is a kind of water cooling equipment, which is a kind of cooling water equipment that can provide constant temperature, constant flow and constant pressure. The working principle of the reactor refrigeration equ...
Посмотреть детали -
On November 3-5, meet at Chongqing International Expo Center [CIPM] Booth S3-07-2
1999LNEYA Exhibition Name: National Pharmaceutical Machinery Expo and China International Pharmaceutical Machinery Expo Exhibition time: November 3-05, 2020 Booth No.: s3-07-2 Exhibition address: Chongqing International Expo Center
Посмотреть детали
工業冷水機製造商 LNEYA Taiwan











