What should I pay attention to when choosing an evaporator for an ultra-low temperature chiller?
The evaporator in the ultra-low temperature chiller is one of its four major components, so performance is more important.
The selection of ultra-low temperature chillers needs to pay attention to the influence of liquid level on the evaporation temperature. Due to the influence of the height of the refrigerant liquid column, the evaporation temperature at the bottom of the flooded evaporator is higher than the evaporation temperature of the liquid surface. The evaporation temperature of different refrigerants at different liquid levels is affected differently by the height of the static liquid. Regardless of the refrigerant, the lower the evaporation temperature of the liquid surface, the greater the influence of the hydrostatic height on the evaporation temperature. Therefore, only when the evaporation pressure is high, the influence of the hydrostatic height on the evaporation temperature can be ignored. When the evaporation temperature is low, it cannot be ignored. In other words, it becomes uneconomical to use a flooded evaporator at this time.
If the evaporation temperature is lower than the freezing temperature of the refrigerant, the refrigerant may freeze. In the subsequent flow of the refrigerant, the temperature of the refrigerant is low, and the possibility of freezing is high. When water is used as the refrigerant, theoretically, the temperature of the inner wall of the tube can be as low as 0°C. However, for safety reasons, the temperature of the inner wall of the pipe at the outlet end of the next process is usually kept above 0.5°C. In the case of brine as the refrigerant, according to the same principle, the temperature of the inner wall of the tube should be higher than the freezing temperature of the refrigerant by more than 1°C.
When the refrigerant flows through the evaporator, pressure loss is caused, which will inevitably make the pressure p2 of the refrigerant at the outlet of the evaporator be lower than the pressure p1 at the inlet, thereby reducing the suction pressure of the compressor, resulting in a decline in the refrigeration capacity.
According to different models, the choice of evaporator is different. For example, the box-type small ultra-low temperature chiller uses a water tank coil type evaporator; the open-type small ultra-low temperature chiller and the screw-type small ultra-low temperature chiller use shell and tube Type evaporator; for acid and alkali resistant ultra-low temperature chillers, you can choose titanium tube evaporator or stainless steel plate exchanger; there are many options, of course, it can be customized according to user needs.
The ultra-low temperature chiller evaporator is generally designed and equipped by the ultra-low temperature freezing test manufacturer. It is recommended that users check the configuration problems when choosing the ultra-low temperature chiller manufacturer.
Похожие рекомендации
-
The Application of Cold Plate Freezer
1762The refrigeration system of cold plate freezer adopts secondary super-cooler technology with the rapid refrigeration and low limiting temperature. It uses imported brand name semi-hermetic piston compressors, semi-hermetic piston compound compress...
Посмотреть детали -
2020 CPhI China The 20th World Pharmaceutical Raw Materials China Exhibition
1778December 16-18 Booth number: W5P08 Shanghai New International Expo Center (Pudong) On December 16-18, 2020, the 20th World Pharmaceutical Raw Materials China Exhibition (CPhI China 2020) will be held at Shanghai Pudong New International Expo Cente...
Посмотреть детали -
LNEYA криогенное охлаждение - новый метод экстракции в индустрии конопли
1906The extraction stage of cannabis processing is important for producing the best yield and compounds suitable for the desired application. For example, excess lipids, waxes, solvents and other components. On the other hand, formulations that requir...
Посмотреть детали -
LNEYA борется с "НКП" и благополучно возобновляет производство
2407НКП окутывает дымкой новый 2020 год, но момент, когда все восстановится, никогда не будет пропущен. В настоящее время для многих предприятий по всей стране операционное давление и ответственность очень тяжелы. Однако LNEYA ...
Посмотреть детали
工業冷水機製造商 LNEYA Taiwan