Fully closed cycle high viscosity fluid refrigeration heating flow control system
Применение:
1. The tested object is connected to a test platform adapter.
2. The internal parts of the parts are cooled, heated, flow controlled, and pressure controlled by various lubricating oils, hydraulic oils, aviation fuel, fuel oil, and coolant.
Тестовый компонент должен пройти через определенный температурный профиль и зарегистрировать изменения температуры.
4. When conducting the tolerance test, perform the thermal shock test, and the rapid temperature drop control usually takes place in an infinite loop.
Визуализация, хранение данных и анализ отчетов
6, temperature control equipment can be flexibly connected to other test platforms
7. Equipped with a powerful circulation pump to ensure the delivery of high viscosity liquids.
8. The range of temperature changes is usually from -50 to 200 degrees (which can be made wider).
9. The proportional control valve is used to control the flow output, and the high-precision control total range is adjusted from 5% to 100%. The flow control range is large, and the minimum flow rate can be controlled from 3L/H to a maximum of 100m3/H.
10, pressure control 0.1bar ~ 20bar
11. The fully enclosed circulation system avoids the contact between the medium and the outside air, ensures no condensation, and avoids oxidation of the medium.
Похожие рекомендации
-
Temperature control mode of automatic control system of reaction kettle
1990The automatic control system of LNEYA reactor is the equipment used for temperature control of the reaction kettle. What are the temperature control methods of the automatic control system of the reactor? How are you controlling the temperature? T...
Посмотреть детали -
How to choose low temperature and high temperature aging test equipment?
2175The refrigeration capacity and temperature range of materials in different industries are different. Generally speaking, the cooling capacity is divided into 80kw, 120kw, 180kw, 240kw, 360kw, and the cooling temperature ranges from -25°C to -5°C. ...
Посмотреть детали -
Precautions for the use of chemical refrigeration and heating circulation systems
1896In chemical production, the reaction will generate heat, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause danger. The existing heating system of the reactor is relati...
Посмотреть детали -
Когда выбирать систему контроля температуры TCU?
1927First of all, we need to know that the reaction kettle generally needs to carry out the necessary temperature control along with the chemical reaction of the material itself. Through the temperature change of the circulating medium in the jacket ...
Посмотреть детали