Чем отличаются гликолевые чиллеры от чиллеров с водяным охлаждением?
Как гликолевые охладители, так и чиллеры могут использоваться для удовлетворительного отвода тепла, выделяемого в процессе производства. Принципиальное различие между этими двумя типами охладителей заключается в различии их температуры замерзания и способности к теплопередаче. ...
Pure ethylene glycol or a mixture of ethylene glycol and water has a much lower freezing point than pure water. This means that glycol-based chillers are better suited for low-temperature environments. In contrast, water has a better ability to retain and conduct heat in the associated process than glycol mixtures. As a result, the heat transfer efficiency for water chillers will be higher than for glycol chillers.
Water: Using water as a coolant is an economical method as water is readily available at minimal cost in most cases. Alternatively, purified water (deionized water, reverse osmosis) can be used in water-based chillers for greater cooling efficiency.
Ethylene Glycol: Ethylene glycol-based coolants consist of either ethylene glycol or propylene glycol. Although the two variants have similar physical properties, they should never be mixed. The main benefits of glycol coolants are improved corrosion resistance and freeze protection.
Why use ethylene glycol for cooling?
Using a glycol-water mixture as a coolant has several advantages over using plain water as a coolant. These advantages are due to its unique physical properties, which include a lower freezing point than water.
Похожие рекомендации
-
Performance Test of Household Refrigerator Designed by Environmental Chamber Sales
2356Many performance items of household refrigerators are tested under a specific environmental condition. The thermal condition of the air distribution in the environmental chamber is more severe than that in the general artificial constant temperatu...
Посмотреть детали -
Collocation Requirements For Lab Water Chiller
2037The lab water chiller is a relatively advanced cryopreservation equipment, which is suitable for blood stations, hospitals, health and epidemic prevention systems, scientific research institutes, electronic industry, chemical medicine, biological ...
Посмотреть детали -
Semiconductor laser automatic temperature control equipment accessories fault solution
2159Semiconductor laser automatic temperature control compressor frosting, may be circulating water circulation or valve is not open, check the water valve, all pipelines, to ensure smooth, install short-circuit pipeline. It may be that the circulatin...
Посмотреть детали -
Как установить -60°C криогенный охладитель производители оборудования
2357Криогенные холодильники -60℃ используются в холодильной и химической промышленности, поэтому на какие вопросы следует обратить внимание при установке? Профессиональные производители LNEYA говорят вам, что вы должны установить в соответствии с инструкцией...
Посмотреть детали