How to solve the problem of poor cooling performance of the heat transfer oil circulation system?
Some heat-conducting oil circulation systems will not be as good as before after 3 months of use. At this time, it is recommended to contact the professional after-sales department to check the user’s power supply and whether the equipment is normal. The test heat conduction oil circulation system is set to cool operation, and the working pressure is 4.5kg/cm2. Considering that the variable frequency heat transfer oil circulation system uses the electronic expansion valve to throttle, it is not accurate to judge the fault only by the working pressure. Therefore, the outdoor working current is measured again. The measurement finds that the working current is only 10.5A, which is much smaller than the rated value, and the fault is determined as “ Lack of refrigerant.”
Then, first find out the refrigerant leakage part of the heat transfer oil circulation system. Try to open the mechanism heat, use the washing spirit liquid to coat the joints for leak detection, and find that the joint is not tightened, which is the cause of refrigerant leakage. After tightening, check the leak again to make sure the pipeline is intact and then charge the system with refrigerant.
The heat transfer oil circulation system uses the “constant flow charging method”. In order to ensure the accuracy of the refrigerant charge, the exhaust pipe temperature sensor is first suspended. After starting up, use the ammeter to measure the current on the outdoor power line of the heat transfer oil circulation system. As the refrigerant replenishment increases, the current will gradually increase. When the rated current value reaches 12A (the 70-type inverter cabinet is 16A), the refrigeration The dosage of the agent is appropriate. This method is often used during home repairs.
If the heat transfer oil circulation system is overhauled or the leak is too large, and the refrigerant has leaked out in the system for a long time, the refrigerant can be charged by the quantitative method. First, the system is evacuated, and vacuuming or external air evacuation can be used. Then, the system is filled with refrigerant according to the standard. If the external air is emptied, it should be slightly less than the standard amount and in the cold state. These are the reasons why after a few months of use, suddenly become uncooled or poorly cooled.
LNEYA provides professional heat transfer oil circulation system, which is mainly engaged in professional brand equipment, with safe and reliable quality. If you need it, please come and purchase it.
Похожие рекомендации
-
Instructions for use of the enclosed cooling and heating circulator of LNEYA, a chiller manufacturer
1797In the chemical and pharmaceutical field, the closed cooling and heating circulator is a cooling and heating temperature control device that cooperates with various types of reactors, jacketed tanks, reactors, extraction equipment and other equipm...
Посмотреть детали -
Необходимость испытательной системы для батарей электромобилей новой энергии
1715The battery performance of new energy vehicles directly determines the experience of new energy vehicle end users. The electric vehicle battery test system needs to test the performance reliability of new energy vehicle batteries. With the develop...
Посмотреть детали -
What reactions are microchannel reactors suitable for?
2137In recent years, micro-chemical technology has developed rapidly, and micro-channel reactors have attracted more and more attention. Microchannel reactors are manufactured with the help of special micromachining technology. They have the advantag...
Посмотреть детали -
Ввод в эксплуатацию и остановка низкотемпературного циркуляционного охладителя
2094When the low temperature circulating chiller is turned on, it can be automatically turned on when the manual start is selected. The automatic start-up needs to open the compressor exhaust shut-off valve, start the cooling water pump and the coolan...
Посмотреть детали