Basic structure manual of industrial chiller
Industrial chillers are composed of compressors, condensers, evaporators, expansion valves and other accessories.
1. Компрессор: В промышленных холодильных системах компрессор - это источник энергии, обеспечивающий охлаждение. Компрессор используется для повышения давления хладагента в системе, что позволяет хладагенту циркулировать в холодильной системе для достижения цели охлаждения.
2. Condenser: The high temperature and high pressure Freon of the refrigeration system enters the condenser after coming out of the compressor, releases a lot of heat to the cooling medium, and is then cooled and liquefied.
3. Evaporator: When the freon liquid in the refrigeration system enters the expansion valve for throttling and is sent to the evaporator, it belongs to the vaporization process. At this time, it needs to absorb a lot of heat, gradually reduce the valence and mass temperature, and achieve the effect of cooling.
4. Expansion valve: In the flow chart of the refrigerant system of the industrial chiller, we found that there is a small part between the condenser outlet and the evaporator inlet, which is called thermal expansion valve. It is a throttling and decompression component that reduces the condensing pressure of the refrigerant to the evaporating pressure. Therefore, its role in the refrigeration system is essential. It is connected with the refrigeration compressor, evaporator and condenser, also known as the four major components of the refrigeration system.
5. Other accessories: including drying filter and high and low pressure controller. The filter drier is not removable. The internal structure adopts molecular sieve structure, which can remove a small amount of impurities and moisture in the pipeline, thereby purifying the system. High and low pressure controllers play a protective role in the refrigeration system.
Похожие рекомендации
-
Ic test equipment manufacturer test project description
2227Ic test equipment manufacturers need to pay attention to the test process when conducting project testing. Users can make the ic test equipment run more efficiently through detailed understanding. The ic test equipment is responsible for the exclu...
Посмотреть детали -
Блок управления температурой реактора TCU с ПИД-регулятором
2173LNEYA reaction kettle temperature control unit tcu adopts PID control loop, which has certain applications in many fields. The reaction kettle temperature control unit tcu of PID control loop adopts fully closed cycle refrigeration system, with fa...
Посмотреть детали -
Introduction of LNEYA Heating Cooling Circulator Thermostat
2287Nowadays, the problem that plagues the pharmaceutical and chemical industry is the problem of temperature control. With the increasing industry demand and temperature control requirements of the pharmaceutical and chemical industry, the use of hea...
Посмотреть детали -
Operation and maintenance of chiller cooling system for alternating high and low temperature tests
2183The operation method of the chiller cooling system for alternating high and low temperature tests: 1. Confirm whether the state of the relevant valves in the unit meets the start-up requirements. 2. Supply power to the electrical control device o...
Посмотреть детали