Как низкотемпературный охладитель подходит для производства пресс-форм?
Everyone knows that the use of low temperature chillers is relatively extensive, especially in the mold industry.
When the low temperature chiller is used to cool the mold, the mold is generally cooled together with the injection molding machine. Generally speaking, the mold is equivalent to a heat exchanger, and the heat is transferred from the mold to the mold and then from the mold to the cooling medium for cooling. Everyone knows that mold molding is inseparable from the function of cooling. When choosing a low-temperature chiller, try to choose a low-temperature chiller with better quality and higher cost. The relative operating power is higher than that of ordinary ones. If the low temperature chiller is used, it can increase the certain output and achieve a certain profit in a long time.
In the practical application of low temperature chillers and molds, the temperature difference of ice water at the inlet is determined according to the product requirements. In many cases, the temperature difference is 3-5 degrees, which is more ideal. The smaller the temperature difference, the more The same amount of ice water required for the same heat to take away, on the contrary, the required flow is very small.
In addition, when using a low-temperature chiller, it is necessary to continuously check the water quality of the low-temperature chiller. Once the water quality changes for a long time, it will cause some corrosion. If it is not treated in time, it will produce scale and can produce a certain separation. Heat, when severe, will reduce the effect of the conversion. Therefore, when configuring a low-temperature chiller, the water quality must be selected well. In addition, the scale can be treated regularly or in a timely manner.
In the process of cooling with a low-temperature chiller, the pressure of ice water should be selected. Of course, our microcomputer function can meet everyone’s requirements and is quite convenient.
Another point is that the pipeline of the low-temperature chiller must be insulated and insulated, otherwise it will cause the loss of cooling capacity, forming dew condensation water on the outer wall, affecting the use of low-temperature chillers.
In fact, when purchasing low-temperature chillers, the more important thing is the quality problem. Since ancient times, it has been a price, since you bought it, you can buy it a little better!
Похожие рекомендации
-
Высокотемпературная обработка неисправностей оборудования для испытания на температурный шок
2177The whole function of Wuxi Guanya LNEYA thermal shock test chamber is computer controlled. It is a self-developed software with a good operation interface, which makes the operation and monitoring of the user simpler and more intuitive. The mainte...
Посмотреть детали -
How to deal with the installation of the hot and cold integrated control machine?
2318Since the thermocouple's thermal inertia causes the meter's indicated value to lag behind the measured temperature, this effect is particularly pronounced when performing rapid measurements. Therefore, thermocouples with thinner thermal electrodes...
Посмотреть детали -
Cooling method for semiconductor testing chiller to meet temperature control requirements
2494The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to stabilize chemical reactions; the electronic manufact...
Посмотреть детали -
Three Common Failures Of Air Cooled Screw Chiller
26641. Communication Failure: Computer controller controls various modules by telecommunication lines and total interface board, so the main cause of communication failure is poor contact or break of communication lines, especially the interface oxida...
Посмотреть детали