How To Choose The Equipment For The Reactor?
The choice of equipment for the reactor needs to be measured by the following points:
1. Heating method: Generally, the electric heating should be greater than or equal to 3 tons, and in the case of the outer half pipe; less than or equal to 3 tons can be heated by water or steam, the temperature is less than or equal to 90 degrees; and the heat transfer oil can be 130 -280 degrees between.
2. Cooling method: generally normal temperature is 25 degrees or more; chilled water is between 5-25 degrees, equipped with a cooling machine; there is also an oil cooling, suitable for high temperature resin, but the temperature should be greater than or equal to 200 degrees.
3. Material: Generally, there are SUS304 stainless steel, Q235 carbon steel, SUS316 stainless steel, etc.;
4. Stirring method: inclined blade type with inclined angle of 45-60 degrees; anchor type with scraping edge scraping; dispersing disc type with 1000/1500/2800 rpm for shearing (for paint or powder, Hot melt adhesive (rubber); and ribbon type for high viscosity with dispersing disc (for hot melt adhesive)
5. Sealing form: generally has mechanical seal, packing seal, double sealing surface, single sealing surface;
6. Structural aspects: generally have outer half tube type (more than or equal to 2 tons); outer jacket type (more than 3 tons); inner coil; no jacket (no heating); inner coil type (suitable for small viscosity, Small fluidity)).
7. The structure of the kettle body: determined according to size, material and thickness;
Wuxi Guanya LNEYA refrigeration heating temperature control system is the first choice for the reactor equipment, ultra-high temperature cooling technology, can directly cool down from 300 degrees high temperature. No heat transfer medium evaporates at high temperature, and continuous control can be achieved with -80 to 190 degrees, -70 to 220 degrees, -88 to 170 degrees, -55 to 250 degrees, and -30 to 300 degrees without pressurization. temperature.
Похожие рекомендации
-
Аксессуары для систем контроля температуры полупроводниковых холодильников
2124В испарителе, поскольку жидкость испаряется в испарителе полупроводниковой холодильной системы температурного контроля, процесс из жидкости в газ, из-за изменения нагрузки, часть хладагента может быть не полностью испарена...
Посмотреть детали -
Cautions for Ultra-low Temperature Freezer
19581. Requirements of equipment environment: To keep the outside of cryogenic refrigerator clean and ventilated, it is necessary to keep the horizontal position of cryogenic refrigerator stable, and to ensure that there are no sundries around. 2. Man...
Посмотреть детали -
Development Of LNEYA Low Temperature Chiller
1816With the internationalization of the economy, Wuxi Guanya has seized the opportunity. It not only develops rapidly in China, but also actively develops foreign markets, and becomes one of the important enterprises in the development of low tempera...
Посмотреть детали -
Система охлаждения шкафа-холодильника для хранения энергии с жидкостным охлаждением
1976С развитием новых энергетических технологий увеличилось применение контейнерных систем хранения энергии в новых энергетических, фотоэлектрических и электрических станциях. Если температура аккумуляторной батареи не соответствует...
Посмотреть детали
工業冷水機製造商 LNEYA Taiwan











