Меры предосторожности при использовании рециркуляционного охладителя LNEYA
LNEYA’s low temperature recirculating chiller
can be used with supporting instruments (such as rotary evaporators,
fermentation tanks, chemical reactors, freeze-drying equipment,
biopharmaceutical reactors, etc.), with large cooling capacity and fast speed.
The low-temperature circulating chiller can conduct low-temperature and
constant-temperature experiments in the open cold tank inside the machine, or
circulate the low-temperature liquid outside to cool or keep other equipment at
low temperature. There are many precautions when using low-temperature
recirculating chillers. In order to prevent malfunctions, LNEYA lists the
following precautions for your reference:
1. The installation environment of the
low-temperature recirculating chiller must be dry and ventilated, and there
should be no obstacles around the equipment, otherwise it will affect the
normal use of the equipment.
2. The liquid medium added inside the
low-temperature recirculating chiller is particularly important. The liquid
medium is selected according to different temperatures to add different
mediums. The position of the liquid is also very important. The liquid level of
the medium must be about 30 mm below the edge of the liquid tank, otherwise the
heating device will be damaged after power on.
5. The low-temperature recirculating chiller
must do a good job in daily maintenance work, and must ensure that the
appearance of the equipment is dry and clean. Doing a good job in the
maintenance of the equipment is very important to the service life of the
оборудование.
6. After using the low-temperature
recirculating chiller, be sure to turn off the switch button of the equipment
first, and then unplug the power supply. Please do not forcibly unplug the
machine’s power supply during the operation of the machine, as this will cause
great damage to the machine itself.

Похожие рекомендации
-
Precautions for the use of molecular distillation cooling and heating temperature control
1839The SUNDI series of LNEYA refrigeration and heating temperature control system are used together to control the temperature in the process of molecular distillation. What should be paid attention to in use? If the molecular distillation method ca...
Посмотреть детали -
Инструкция по установке высоко- и низкотемпературного термостата на 100 л
1680Высокотемпературный и низкотемпературный термостат 100L использует охлаждающую жидкость в качестве передающей среды для передачи тепла, вырабатываемого другими приборами или оборудованием, которое необходимо охладить, и отвода тепла наружу через холодильн...
Посмотреть детали -
Explosion-proof hot and cold machine winter maintenance instructions
2438When the explosion-proof type hot and cold integrated machine is used at the end of the day or when it is not used by the standby, be sure to disconnect the cooling water connection pipe, clean the remaining cooling water in the pipe, and store it...
Посмотреть детали -
Analysis of operating parameters and working conditions of automobile power module cooling system
2264Before choosing, you need to know what factors are related to the operating parameters and working conditions of the automotive power module cooling system. Then, from which aspects? 1. Evaporating pressure and evaporating temperature In the ope...
Посмотреть детали
工業冷水機製造商 LNEYA Taiwan