Что делать, если компрессоры холодильника 30p перегреваются?
When users purchase 30p Refrigerated chiller, they understand the internal configuration. The compressor is an important accessory in 30p Refrigerated chiller. If it overheats, 30p Refrigerated chiller will be unavailable, then 30p Refrigerated chiller. How to solve the overheating of the compressor?
The compression ratio of any type of 30p Refrigerated chiller should not be too large. The compression ratio is easy to understand, that is, the ratio of the degree of compression of the gas, for example, the previous gas is 10, and the compression is 1, the compression ratio is very high, so it can be concluded that if the compression is high and the value is large, then It is certain that the compressor’s work load will be larger, no doubt. If the compression ratio is too high, the load on the compressor will become large. When the load is large, the work efficiency will decrease and the power consumption will increase. Since the compression ratio of the compressor is increased, the internal temperature is higher, which not only affects the properties of the refrigerant, but also may cause the viscosity of the lubricating oil to decrease, the lubricating effect to be low, and the lubricating oil that does not function as a function in the compressor. , will lead to increased compressor wear rate.
In addition, the high pressure, that is, the exhaust pressure, will also become higher due to the increase of the compression ratio, which will bring a greater heat dissipation burden to the condenser. If the fan or the water cooling system cannot improve the heat dissipation capacity, the heat dissipation effect of the condenser may be deteriorated. The 30p Refrigerated chiller system will not be able to handle the heat dissipation of the equipment.
If the compression ratio of 30p Refrigerated chiller is too high, it should be checked for blockage. It is recommended to replace the filter. The filter can improve the filter to filter the impurities that may be generated by the 30p Refrigerated chiller system and the impurities that may be generated in the frozen oil. To prevent blockage of pipes and valves. It is necessary to consider whether the shortage of refrigerant causes the suction pressure. If the suction pressure is too high, the compression ratio is too high and the exhaust temperature is too high. That is, the compression ratio as well as the exhaust pressure and the exhaust temperature can be lowered by increasing the suction pressure. It is also possible to perform separate additional cooling of the compressor, and also to solve the problem that the exhaust pressure is too high and the exhaust temperature is too high when the compression ratio is too high. Consider choosing the right refrigerant to control the compression ratio of the compressor.
Once the 30p Refrigerated chiller compressor has overheated, it needs our operators to solve it in time. If an unknown fault occurs, you can contact 30p Refrigerated chiller after-sales personnel to solve it.
Похожие рекомендации
-
В каких отраслях промышленности могут использоваться низкотемпературные охладители?
1763Maybe some of you don't know much about low temp chiller products. The low temp chiller is a kind of professional refrigeration equipment used in industrial production. In recent years, there has been a great demand for different types of low temp...
Посмотреть детали -
Классификация, преимущества и недостатки водоохлаждаемых чиллеров
2323Промышленные чиллеры делятся на промышленные чиллеры с воздушным охлаждением и промышленные чиллеры с водяным охлаждением. Сегодня мы рассмотрим классификацию, преимущества и недостатки чиллеров с водяным охлаждением. Преимущества чиллеров с водяным охлаждением: 1. Инте...
Посмотреть детали -
Микроканальный реактор с термостатическим управлением с воздушным охлаждением компрессор чиллер поиск и устранение неисправностей мет.
2086The air-cooled chiller is a temperature control device that is widely used in the microchannel reactor industry. Wuxi Guanya LNEYA has produced a cold and heat source thermostatically controlled air-cooled chiller for the microchannel reactor indu...
Посмотреть детали -
Каких ошибок в обслуживании следует избегать в криогенной холодильной системе
2135The cryogenic refrigeration system is different from air conditioning system, the medium and low temperature cryogenic refrigeration system in a common sense. It is more special in refrigeration structure, working medium and temperature. It is oft...
Посмотреть детали